Cleaning Device d-800 Page 7
equipment and facility engineering
• If the device is not used, the device cover must always be closed for safety reasons.
Before commissioning, the earthing must be ensured via a sufficiently dimensioned earth
cable (potential equalization)! The connection must be made by a specialist.
• The user has to ensure that nobody is in the danger area of the cleaning device.
• Use only permitted solvents / cleaning media (see chapter 4). These must be free of
Halogenated hydrocarbons (CKW, CFC, TRI, PER, etc.).
• If water (e.g. with additives) is used as a cleaning medium, this must not be discharged into the
sewer system.
• Take into account that the chosen cleaning medium is suitable for use and does not attack surface.
Suitability shall be ensured by the operator in preliminary tests. The manufacturer and / or supplier
does not assume any liability for damages caused by these tests.
• The safety data sheet of the cleaning medium must be observed.
• Use personal protective and chemical resistant protective equipment, e.g. face protection,
protective gloves, protective aprons etc.
• Ensure that the clothing (especially the footwear) is adequately conductive
• Do not place the protective equipment on the device.
• If clothing has been wetted with solvent / cleaning medium, do not smoke in this area. Put off the
contaminated clothing immediately. Risk of skin irritation, allergies, etc.
• Persons wearing moistened clothing must not be exposed to sources of ignition (e.g. welding). Risk
of fire!
• Do not fill any additional cleaning media into the unit, as this may lead to a overflow of the barrel.
• Immediately collect spilled solvent (s) with suitable binders (blinding mica, kieselguhr, etc.) and
dispose it of in accordance with regulations. The water resources law must be satisfied.
• Clean your hands before eating any food or drink. Danger of poisoning!
• Avoid inhalation of fumes and contact with the solvent / cleaning medium.
• Do not add any other liquids to the cleaning medium, such as kerosene, gasoline, chlorinated
hydrocarbons, acids, alkalis.
• When changing the cleaning medium, all valid regulations (e.g. wastewater-regulations) must be
observed!