5
2.1 Work Area
Do not use this equipment in an explosive or combustible environment; otherwise it may
lead to fire.
Use caution when moving the equipment over uneven floors to avoid tipping over or
damage to the emitters.
Keep the working area clean and free of any obstructions.
2.2 Use
To reduce the risk of explosion, DO NOT use in paint spray booths or within 10ft of
spraying operations, as per the requirement of UL 499.
This unit must be operated in a well-ventilated area.
Isolate power supply before removing any covers.
Regular cleaning of tubes and reflectors should be done by using a piece of soft cloth or
cotton with IPA or mentholated spirits l (Note: cleaning must only be conducted after the
machine is disconnected from the power supply and has cooled down if necessary).
Allow 15 minutes for the solvent to dissipate before switching the unit back on.
The machine should be well grounded for safety. The grounding device should be
connected to the proper output port under correct direction. Unauthorized alteration or
change of output port is strictly prohibited. Use of any outlet converter is also disallowed.
If you are ever uncertain, please find a professional electrician to check whether the
grounding is correct. Please make sure the machine is well grounded to avoid electric
shock.
If the lamp / tube fails to work after starting, it may be caused by a loosened outlet plug.
In such a case, just switch off the machine and check that plug is secure in the socket in
the connection box.
Replace any chaffed or damaged cables / wires immediately to avoid the possibility of
electric shock.
Don’t misuse the electric cable. Do not drag the machine with the power cable or pull the
power plug. Keep the power cable away from hot, oily, or sharp objects.
Should the power cable become damaged, ask the manufacturer, service provider or a
professional to replace it to reduce the risk of injury / damage.
For replacement emitters / tube / bulb, only purchase from authorized distributors
2.3 Maintenance and Care
Regular cleaning of tubes and reflectors should be done by using a piece of soft cloth or
cotton with IPA, alcohol or mentholated spirits (Note: cleaning must only be conducted
after the machine is disconnected from the power supply and has cooled down if
necessary). Allow 15 minutes for the solvent to dissipate before switching the unit back
on.
The device should be protected by a 15-Amp slow fuse.
For replacement lamps / tubes, contact your distributor.
2.4 More Information
Always turn the unit off before moving, especially over rough surfaces.
Do not use the equipment in damp or wet locations.