Mixing- and preparation table Painty
Page 9
6.3.
Exhaust Ducting Painty-03
The Painty-03 comes without integrated extraction nozzle, but comes with a preparation for an on-
site air extraction. The on-site air extraction can be connected to the Painty-03 with a Ø150 mm
exhaust hose. The connection is on the roofe of the table.
Figure 3 - Painty-03 - Extraction prepared for diameter 150mm
6.4.
Compressed Air Connection
A compressed air supply is needed for the product.
Operating pressure max.: 600 kPa (6 bar , 87 psi)
Operating pressure min.: 500 kPa (5 bar , 73 psi)
A
pressure regulating valve (Item no.: 10000619)
has to be fitted if the compressed air con-
nection exceeds the required operating pressure. Use only
dry and oil-free air
!
6.5.
Grounding / Earthing
The product has a grounding / earthing connection
and may not be operated without being grounded!
The product has a grounding / earthing cable, which needs to be grounded / earthed safely by a com-
petent person (e.g. electrician).
Customer-provided containers have to be grounded separately!
After proper installation and mounting of the exhaust hose, connection to the compressed air supply
and grounding, the product can be commissioned.