Mixing- and preparation table Painty    

                             

Page 6 

 

4.

 

Zone and Product Classification according to ATEX 

This  product  does  not  have  any  ignition  source  and  is  therefore  not  subject  to  ATEX-Directive 
2014/34/EU. Operation in an ex-zone (e.g. zone 1) is therefore possible.  

 

In accordance with legal requirements, the ATEX zone definition around the product and creation of 
an explosion protection document comes under the responsibility of the "responsible person of the 
company" where the product is placed as this classification is subject to the cleaning fluid used and 
various conditions such as ventilation. 

However, at this point the operator should be supported with general advice to comply with this ob-

ligation. Helpful advice can also be found in EN 12921‐1 and ‐3 and EN 13463

-1. 

If using the product with flammable fluids, the following zone designation can be applied: 

Zone 1 

 The mixing and working area 

 

Zone 2 

 

Surroundings within 1.0 m 

Mark the different zones with appropriate warning and prohibition signs. Markings on the floor can be 
helpful. In the area surrounding the product, open flames and other ignition sources (e.g. welding or 
grinding equipment) are not allowed. In addition, smoking is prohibited. Temporary work causing igni-
tion sources must be approved in writing and appropriate additional safety measures must be applied 
(e.g. remove all combustible materials; firefighting equipment must be on hand in the working area.) 

 

5.

 

Requirements for the Installation Site 

 

Horizontal industrial floor with electrical resistance of max. 10

8

 Ohm. 

 

Dry and protected from frost. 

 

Very good technical room ventilation with 5-7 air changes per hour (Depending on local regu-
lations). 

 

Do not install or operate the product within a radius of 1.5 m from heat sources. 

 

Ensure an ambient temperature of 5 °C 

 40 °C and do not expose the product to direct sun-

light, as this carries a risk of overheating. 

 

Follow the relevant legislative and regulatory safety instructions regarding substances hazard-
ous to water applicable in the country where the product is installed.  

 

Follow the safety regulations according to zone designation. 

 
Space Requirements for Operation and Maintenance 

The product can be placed against the wall or in a corner. A 1.5 m space should be provided in front of 
the product. 

 

 

 

Summary of Contents for Painty-02

Page 1: ...lershausen Tel 49 0 5085 97100 0 Fax 49 0 5085 97100 30 Email info btecsystems de www btecsystems de Painty 02 03 04 Mixing and Preparation Table Operating Manual for Mixing and Preparation Table Pain...

Page 2: ...ts to be the Operator 2 2 Safety Requirements 2 2 1 General Safety 2 2 2 Operational Safety 3 2 3 Hazards from Pneumatic Energy 4 3 Technical Description of the Product 5 3 1 Technical Data 5 4 Zone a...

Page 3: ...ormation in this operating manual the symbols Caution and Notice are used Please note that paragraphs with these symbols need particular attention Caution You will see this symbol whenever attention i...

Page 4: ...turer sup plier is not liable for any damages resulting from improper use The working tables Painty are mixing and preparation tables for paints and solvents This product is for commercial use only bu...

Page 5: ...s with solvents Use of protective clothing Use of eye and face protection Use of pro tective gloves Industrial Safety 2 2 Operational Safety The product may only be operated if o the integrated suctio...

Page 6: ...untry specific workplace exposure limits legislation according to safety data sheets must be documented The limit values of the country specific air pollution and adherence thereto must be observed Do...

Page 7: ...th gratings It has 4 x spray gun holder and a lockable base cabinet with two stable storage shelves made of stainless steel The product Painty 04 has a strong exhaust suction system on the table work...

Page 8: ...lpful In the area surrounding the product open flames and other ignition sources e g welding or grinding equipment are not allowed In addition smoking is prohibited Temporary work causing igni tion so...

Page 9: ...7 6 Transport and Installation The product is delivered packed Unpack the product outside an explosive atmosphere and bring it to the installation site Install the product as described in the followi...

Page 10: ...fire places and not into the exhaust ducts of spraying and drying cabinets In case the exhaust system con ditions at the installation site require a longer exhaust air hose or the instructions in how...

Page 11: ...ing pressure min 500 kPa 5 bar 73 psi A pressure regulating valve Item no 10000619 has to be fitted if the compressed air con nection exceeds the required operating pressure Use only dry and oil free...

Page 12: ...aking and undamaged 4 All functions intact and properly set 5 Grounding Earthing wire connected 6 Extraction works Check for brittleness tight connections etc Remarks Name of inspector _______________...

Reviews: