Mixing- and preparation table Painty
Page 6
4.
Zone and Product Classification according to ATEX
This product does not have any ignition source and is therefore not subject to ATEX-Directive
2014/34/EU. Operation in an ex-zone (e.g. zone 1) is therefore possible.
In accordance with legal requirements, the ATEX zone definition around the product and creation of
an explosion protection document comes under the responsibility of the "responsible person of the
company" where the product is placed as this classification is subject to the cleaning fluid used and
various conditions such as ventilation.
However, at this point the operator should be supported with general advice to comply with this ob-
ligation. Helpful advice can also be found in EN 12921‐1 and ‐3 and EN 13463
-1.
If using the product with flammable fluids, the following zone designation can be applied:
Zone 1
→
The mixing and working area
Zone 2
→
Surroundings within 1.0 m
Mark the different zones with appropriate warning and prohibition signs. Markings on the floor can be
helpful. In the area surrounding the product, open flames and other ignition sources (e.g. welding or
grinding equipment) are not allowed. In addition, smoking is prohibited. Temporary work causing igni-
tion sources must be approved in writing and appropriate additional safety measures must be applied
(e.g. remove all combustible materials; firefighting equipment must be on hand in the working area.)
5.
Requirements for the Installation Site
•
Horizontal industrial floor with electrical resistance of max. 10
8
Ohm.
•
Dry and protected from frost.
•
Very good technical room ventilation with 5-7 air changes per hour (Depending on local regu-
lations).
•
Do not install or operate the product within a radius of 1.5 m from heat sources.
•
Ensure an ambient temperature of 5 °C
–
40 °C and do not expose the product to direct sun-
light, as this carries a risk of overheating.
•
Follow the relevant legislative and regulatory safety instructions regarding substances hazard-
ous to water applicable in the country where the product is installed.
•
Follow the safety regulations according to zone designation.
Space Requirements for Operation and Maintenance
The product can be placed against the wall or in a corner. A 1.5 m space should be provided in front of
the product.