34
Checking the Alignment of Load Cells
Once the load cell assembly has been installed it must be checked for correct
alignment. Using the B-TEK load cell surface level, supplied to authorized dealers,
attach to the lower diameter of the load cell using the integral magnet. The magnet can
be adjusted in and out by turning the set screw.
With the level attached to the load cell, verify that the load cell is aligned both
horizontally and vertically by ensuring that the air bubble is visible between marked
lines.
If the load cell is out of level, adjustments can be made by realigning the foundation
base plate.
Repeat the check with the level to verify that the load cell is aligned correctly.
Continue to readjust the locating plate as needed.
B-TEK Load Cell Surface Level