background image

2

INSTR

UCTION FOR USE AND MAINTEN

ANCE

www.b3c-pesage.fr

9260

(A)

 - 9360

Thank you for choosing the professional compact scale. All the features of this product were 
designed to the state of the art and are optimised for simple and straightforward use. If you 
any queries or problems not indicated in the operating manual, please contact our service.

INDEX

       

INSTRUCTION FOR USE AND MAINTENANCE - WARRANTY 

 ................. 2

  1 - 

GETTING STARTED 

 ..................................................................................... 3

  2 - 

LEVEL INDICATOR 

 ....................................................................................... 4

  3 - 

KEYPAD FUNCTIONS 

 .................................................................................. 5

  4 - 

ZÉRO FUNCTION - 5 - BACKLIGHT FUNCTION 

 ........................................ 6

  6 - 

TARE FUNCTION 

 .......................................................................................... 6

  7 - 

SELECT MODE WEIGHING

 / 

COUNTING 

 ................................................... 7

  8 - 

COUNTING MODE 

 ........................................................................................ 7

  9 - 

ACCUMULATION FUNCTION 

 ...................................................................... 7

  10 - 

CALIBRATION 

 ............................................................................................ 8

  11 - 

BATTERY OPERATION 

 ............................................................................... 9

  12 - 

TECHNICAL DATA 

 .................................................................................... 10

  13 - 

SPARE PARTS 

 ...........................................................................................11

INTENDED USE

The scale is used for weighing and counting products. This scale is intended for internal operations. 

The scale complies with the type described in the EC type Approval Certificate as well as the appli

-

cable requirement of EC Directives 89/336/EEC and 73/23/EEC.

SAFETY INSTRUCTIONS

Before using the scale, please read with care the information given in the op-

erating manual. It contains important instructions for installation, proper use 

and maintenance of the appliance.

B3C SAS shall not liable for damages arising out of failure to heed the following instructions: When 
using electrical components under increased safety requirement, always comply with the appropriate 
regulations. Never perform work on the appliance while the power is switched on. Improper installation 
will render the warranty null and avoid. Ensure the voltage marked on the power supply unit matches 
your mains power supply. The device meets the requirement for electromagnetic compatibility. Do not 

exceed the maximum values specified in the applicable standards.

Summary of Contents for Serenite 9260(A)

Page 1: ...9260 A 9360 b3c pesage pesage w w w b 3 c p e s a g e f r 9260 A 9360 Ver 2014 EN September BC 9260 A 9360 OPERATING MANUAL GB Compacts scales...

Page 2: ...ded for internal operations The scale complies with the type described in the EC type Approval Certificate as well as the appli cable requirement of EC Directives 89 336 EEC and 73 23 EEC SAFETY INSTR...

Page 3: ...f there is permanent electrostatic interference we recommend to connect the platform with the ground The scale is a measuring instrument Air currents vibrations rapid changes in temperature and direct...

Page 4: ...w When the transportation will be made please install the protection screw on the machine to avoid any damage sensitive components 2 LEVEL INDICATOR The scale is equipped with a level indicator on the...

Page 5: ...an press this key the weight will become 0 Tare the weight of a container Indicate the net weight Input sample size To modify the backlight In the calibration mode to change the value 0 9 Accumulate w...

Page 6: ...ht will be effective When the weight is zero for about 8 seconds the backlight will go off automatically bl 2 The backlight will always be on bl 3 The backlight will be turned off 6 TARE FUNCTION Tare...

Page 7: ...ill show or pcs 9 ACCUMULATION FUNCTION In weighing or counting mode make it to zero place the goods 1 After the display is stable press the key to enter into accumulation mode 2 After accumulation to...

Page 8: ...ble press the key Auto calibration is finished WITH AN KNOWN WEIGHT 1 Turn on scale 2 During the scale in self testing press the and keys about 3 seconds 3 When the display shows CC to change the figu...

Page 9: ...ged If it the led is red the battery is nearly discharged If it the led is yellow the battery is increasing the charge level NOTE The battery should changed if the scale is not used for long time 12 T...

Page 10: ...07 31 Load cell 15kg 0 2g 3 4 19020007 32 Load cell 15kg 0 5g 3 5 19020007 41 Load cell 30kg 0 5g 3 6 19020007 42 Load cell 30kg 1g 9 0210002 CPU Main board 10 0210001 LCD Display board 11 0210003 Key...

Page 11: ...ENGLISH 11 3 1 3 2 3 3 3 4 3 5 3 6 1 2 9 10 11 12 3...

Page 12: ...9260 A 9360 ES Balanzas electr nicas 9260 A 9360 IT Bilance electroniche 9260 A 9360 ND Electronische weegschaal Reeks 9260 A 9360 POR Balan as industriais 9260 A 9360 The indicated balances respect t...