Main cleaning
The main electrical switch shall be at the
0
position and lock it.
Observe the safety instructions at the beginning of this manual.
Wear protective clothing during cleaning and sanitation operations.
Observe the specific national regulations for the cleaning agents and
disinfectants used.
Operation
Cleaning Agent
Device / Method
Remarks
Main Cleaning
2
– 5% P3-topax 17 *
Foam with low-
pressure foaming
device
From bottom to top
reaction time 15
minutes
For removing calcareous deposits, use 1 time
per week cleaning foam 2
– 5% P3-topax 56
instead of P3-topax 17
From bottom to top
reaction time 15
minutes
Drinking water at
60°C
Rinse with low
pressure, max 30 bar
Carefully from top to
bottom
Check
Visual
Sanitation
1% P3-topax 91
Low-pressure
spraying, max 30 bar
From top to bottom,
reaction time about
10
– 15 minutes since
contingent upon germ
spectrum; refer to
product data sheet
Rinsing
Drinking water max
20°C
Low pressure,
max. 30 bar
Rinse again carefully
* To avoid white deposits, P3-topax 17 should not be foamed on hot surfaces.
The cleaning agents P3-topax 17 and P3-topax 56 recommended the avoidance of
painted areas of the machine due to aggressive cleaning properties of the products..
After cleaning run the machine briefly and grease to remove any cleaning fluid that may have
penetrated the bearings.
Correctly dispose of cleaning agents that are ecologically harmful.