Application of
Disassembly
3 - 74
Needle-presser module
Application o
f
Disassembly
Application of Disassembly
13
Removal of Needle bar supporter assy and Thread guide plate
1. Remove the screw (screw, bind M3x5) to remove the plate from the needle bar supporter assy.
Remove the screw (screw, bind M2x4) from the shaft, and then pull out the shaft from the needle bar
supporter assy. Pull out the shaft from the shaft bushing on the upper unit holder assy.
2. Pull out the needle bar supporter assy from the upper unit holder assy while pushing the position “A”.
3. Remove the thread guide plate.
Screw, Bind M2X4
Screw, Bind M3X5
Upper unit holder assy
Shaft bushing
Thread guide plate
“A”
Shaft
Screw, bind M2x4
Needle bar supporter assy
Shaft
Plate
Screw, bind M3x5