Application of
Assembly
3 - 203
Embroidery unit
Application o
f
Assembly
Application of
Assembly
12
Attachment of CW switch assy
1. Attach the cut work switch assy to the needle plate SW holder with the hook. Set the needle plate SW
holder to the CW switch assy.
2. Attach the CW switch assy to the ES base cover assy with the two screws (taptite, bind B M3x10).
3. Set the lead wire assy cut work switch to the securing fixtures, and attach the rubber to the ES base
cover assy.
*Key point
• Refer to
"Wiring of Cut work switch assy"
Taptite, Bind B M3X10
CW switch assy
ES base cover assy
Needle plate SW holder
Cut work switch assy
Rubber
Taptite, bind B M3x10
Taptite, bind B M3x10
Lead wire assy
cut work switch