Basic of
D
isassembly
Basic of Disassembly
2 - 18
Electric parts and Main motor unit
Basic of
D
isassembly
3
Removal of Power unit
1. Remove the power switch assy from the SW holder. Remove the screw (screw, pan (S/P washer)
M4x8) to remove the inlet assy from the base plate. Remove the three screws (screw, pan (S/P washer)
M4x10DB) to remove the clip and the power unit, and pull out the lead wire assy power-main and the
lead wire assy motor drive from the hole of arm bed.
2. Release the lead wire of inlet assy from the securing fixtures of power unit, and then unlock the
connector of inlet assy to disconnect it from the connector of power unit.
Refer to 3 - 29 Disassembly of Power unit.
Screw, Pan (S/P washer) M4X10DB
Screw, Pan (S/P washer) M4X8
Inlet assy
Connector of inlet assy
Screw, pan
(S/P washer) M4x8
Screw, pan
(S/P washer)
M4x10DB
Power unit
Connector of
power unit
Lead wire assy power-main
Lead wire assy
motor drive
Base plate
SW holder
Power switch assy
Clip