Basic of Assembly
2 - 39
LED lamp / Upper driving mechanism
Basic of Assembly
Basic of Assembly
2
Attachment of Needle-presser module
1. Attach the retaining ring E5 to the shaft, and then attach the shaft to the needle-presser module.
2. Set the needle-presser module to the mounting position of arm bed, and align the positioning hole of
adjusting plate assy with the boss of arm bed. Attach the presser plate A to the arm bed with the two
screws (taptite, bind S M4x10), and then attach the presser plate B to the arm bed with the two screws
(taptite, bind S M4x10).
3. Tighten the screw (screw, pan (washer) M3x18) temporarily to the needle-presser module.
*Key point
• Fully tighten the screw after performing
"Adjustment of Needle clearance"
4. Attach the IMT holder to the arm bed with the two screws (screw, bind M4x8).
Refer to 3 - 149 Needle-presser module.
Screw, Pan (washer) M3X18
Screw, Bind M4X8
Taptite, Bind S M4X10
Screw, pan (washer) M3x18
Taptite, bind S M4x10
Presser plate B
Screw, bind M4x8
Presser plate A
IMT holder
Taptite, bind S M4x10
Retaining ring E5
Shaft
Boss
Needle-presser module