Raise
Lower
Screw A
Eccentric shaft
Presser foot bar
Screw B
Needle plate
2. ADJUSTMENT OF NEEDLE AND PRESSER FOOT HEIGHT
a) Height of needle
Turn handwheel, and bring the needle to the highest position.
Loosen screw "A", and turn the eccentric shaft to clockwise or counter-clockwise.
Clockwise ------------------- Lower needle
Counter-clockwise--------- Raise needle
b) Height of presser foot
Raise the presser foot lifter. Loosen screw "B", and move the presser foot bar to
raise or lower.
You are required to check the clearance between needle and presser foot.
2
Needles
Needle position
Height of needle
Needle plate
11.2
+0.1
Right Needle
Organ
ELx705CF 90/14
Organ
HAx1SP/CR 90/14
Organ
HAx1SP/CR 75/11
Organ
ELx705CF 90/14
Needle
plate
12.5
+0.05
C
3
Needle
Needle
plate
Right
O
2
Needle
10.6
+0.1
Needle plate
11.5
+0.1
Right Needle
SX, DX, AT
ATW
BLCS(3)
BLE5,BLE8
BLE8W