27
Using the Touch Screen
Displays on the Handlebars
Figure 22
The Baby Lock Crown Jewel III has touch-screen dis-
plays on the front and rear handlebars. Settings may be
changed at either of these locations.
Main Screen
Manual Mode Screen
Button Functions:
Pressing the “Regulated” button while in the Man-
ual Mode Screen will toggle to the Regulated Mode
Screen. The current stitching mode is displayed at
the top left corner of the screen. Different options
are available depending upon which mode the sys-
tem is in (
Figure 22
).
Needle Stop
The Needle Stop setting enables you to specify
whether you want the needle to end in the up or
down position when you stop quilting (
Figure 23
).
If you select Down, when you press the stop button
on the right handlebar, the needle ends in the down
position. If you select Up, the needle ends in the
up position when you press the stop button on the
right handlebar. Switch between the up and down
position by pressing the Needle Stop button.
Quick-Set Tension
The tension box (
Figure 24
) on the Main Screen
shows the current tension setting as a numeric val-
ue. As you turn the tension dial clockwise to tighten
the top tension, the number increases in increments
of five. As you turn the tension dial counterclock-
wise to loosen the top tension, the number decreas-
es in increments of five. The faster you turn the dial,
the faster the numbers increase or decrease.
After setting the bobbin tension, test the top ten-
sion by stitching on a fabric scrap on the edge of the
quilt batting and backing. Increase or decrease as
needed until you have achieved balanced tension.
Make a note of the type of thread (weight, brand,
color) you’re using and the tension value. You will
be able to quickly and easily set the tension when
you use this same thread again in the future.
Figure 23
Figure 24
Summary of Contents for Crown Jewel III BLCJ18-3