4 - 8
Test mode
6. [TRIM MOTOR TEST]
[MOVE ORIGIN POSITION] : Returns the trim (thread cut) motor to its origin.
[MOVE TRIM MOTOR]
: Moves the trim (thread cut) motor.
[TRIM ON OFF]
: Turns the trim (thread cut) motor on and off.
[TRIM MANUAL]
: Cuts the thread.
[CLOSE]
: Closes the <TRIM MOTOR TEST> screen.
7. [WIPER/JUMP MOTOR TEST]
[MOVE ORIGIN POSITION] : Returns the wiper and jump bracket motor to their origins.
[MOVE WIPER]
: Moves the wiper.
[WIPER ON OFF]
: Turns the wiper on and off.
[MOVE JUMP]
: Moves the jump bracket.
[JUMP ON OFF]
: Turns the jump bracket on and off.
[CLOSE]
:Closes the <WIPER/JUMP MOTOR TEST> screen.
8. [PICKER MOTOR TEST]
[MOVE PICKER] : Moves the picker motor.
[PICKER ON OFF] : Turns the picker on and off.
[<][>]
: Sets the picker drive over-pulses. (Determines the position the picker turns on.)
[CLOSE]
: Closes the <PICKER MOTOR TEST> screen.
Use for cutting blade replacement
Use to inspect wiper blade. Should be flat and smooth
Normal pulse should be set to "2". If customer changes to different
style bobbin, the pulse number may need changed to compensate
.