BAC Document Number: Easybond MKII Manual V03
28/08/13
Page
14
of
32
STEP TWO
Figure 5
DO NOT STRAIGHTEN THE KINKED END OF THE PIN FUSE WIRE.
The legs of the pin holder must be adjusted as necessary to ensure a firm grip of the pin while
maintaining concentricity with the ferrule holder.
Important:
Under no circumstances should a brazing pin which has been inserted and then
removed from the gun be re-inserted and used for brazing without checking the kinked
end profile and fuse wire connection to pin.
7.3 ADJUSTMENT OF BRAZING GUN
Before connecting the earth device to the steel, adjust the brazing pin "Lift Height" as
follows:
Hold the cable lug or stinger flat on the steel surface (for direct pin connection). Insert a loaded
brazing pin into the hole in the lug and press the gun/ferrule against the surface of the lug
evenly overcoming the internal spring. Turn the ferrule holder until the white adjustment
indicator tube is flush with the gun's rear face. The brazing gun should now be correctly set, as
illustrated in
STEP THREE – figure 6.
When using threaded brazing pins, i.e. M8 brazing pin, the ceramic ferrule must be flat against
the steel surface when checking the white adjustment indicator tube.
STEP THREE
Figure 6