background image

World Headquarters

621 Hunt Valley Circle

New Kensington, PA 15068  USA

Phone: 724-334-5000 • Fax: 724-334-5001

Toll Free: 1-800-736-4666

Website: www.MyBacharach.com

E-mail: help@MyBacharach.com

TEST

ADJUST

FINISH

Insert probe at the appropriate sampling point based on equipment type (be sure to avoid 

dilution of the gas sample) 

Review all combustion data from 

various sources:
•  Hold Screen

•  Data previously saved to memory

    (optional)

•  Printout (optional)

Allow instrument to purge after a 

test

Start (RUN) and Stop (HOLD) Test

Forced Air Furnace

Hot Water Tank

Condensing Furnace

or Boiler

Fan Assist or

Power Vented

Furnace or Boiler

Boiler

O

2

, CO, Stack Temp

Undiluted

Flue Gas

O

2

, CO, Stack Temp

Combustion Air

O

2

, CO, Stack Temp

O

2

, CO, Stack Temp

O

2

, CO, Stack Temp

Print data (F1 button) and/or Save data

(F3 button) to memory if desired

Run 

 Nat Gas

T-STK   

  374 °F

T-Air   

   68 °F

EA 

        44.8 %

CO(0)          116 ppm

Run 

 Nat Gas

O

2

 

         7.0 %

CO 

         107 ppm

Eff 

        80.9 %

CO

2

 

         7.9 %

Toggle

Between

Run and

Hold Modes

Scroll Bar

Indicates

More Items

Print

Screen

Display

Main

Menu

Save Results

to Memory

161

8 to 16 in.

(20 to 41 cm)

Made in USA

IrDA

Printer

Adjust combustion equipment as 

needed based on combustion data 

and manufacturer recommendations 

for the combustion device under test
Retest combustion device to verify 

proper/optimal operation

Hold  

Nat Gas

O

2

 

         7.0 %

CO 

         107 ppm

Eff 

        80.9 %

CO

2

 

         7.9 %

BACHARACH, Inc.

    InTech

  SN: AB1234

Time: 12:25:41

Date: 02/8/16

Fuel

NGAS

O  

 

7.0 %

CO 

 

107 ppm

Lambda  

1.5

CO  

 

7.8 %

CO  Max     11.8 %

T-STK        190  C

T-AIR       20.0  C

qA 

       9.5 %

Eta 

      90.5 %

Eff 

      80.9 %

CO/CO2       0.0014

CO(O)         161 ppm

AVG SMOKE     ***

OIL DERIV     ***

BOILER TEMP   *** C

=========================

-------------------------

Comments:

2

2

O

O

2

O

Bridge Street HVAC

Outer Kensington West

London,ENG  SW1J 3

RE-TEST

BACHARACH, Inc.

    InTech

  SN: AB1234

Time: 12:25:41

Date: 02/8/16

Fuel

NGAS

O  

 

7.0 %

CO 

 

107 ppm

Lambda  

1.5

CO  

 

7.8 %

CO  Max     11.8 %

T-STK        190  C

T-AIR       20.0  C

qA 

       9.5 %

Eta 

      90.5 %

Eff 

      80.9 %

CO/CO2       0.0014

CO(O)         161 ppm

AVG SMOKE     ***

OIL DERIV     ***

BOILER TEMP   *** C

=========================

-------------------------

Comments:

2

2

O

O

2

O

Bridge Street HVAC

Outer Kensington West

London,ENG  SW1J 3

Turn off instrument (hold PWR key)
Disconnect probe
Clean then store the instrument and 

probe.

Right Arrow

Displays QR

Code for

Reporting App

Up and Down Arrows

Scroll Display

(North

American

Version Only)

(Sample Prin

tout

fr

om Sieg

ert V

er

sion)

Reviews: