Troubleshooting (continued)
Problem Erratic response in all leak
positions.
Cause
1
Filter is clogged.
2
Dirt in sensor.
3
Short circuit in sensor.
4
Atmosphere contaminated
with excessive refrigerant
gas.
Solution
1
Replace filter (3015-0784).
2
Remove sensor and blow it
out with clean air (not over
10 psi). If unsuccessful,
replace sensor (3015-0486).
Replace filter (3015-0784).
3
Replace sensor (3015-0486).
4
Ventilate Area.
Problem Responds continuously only
in small leak position.
Cause Excessive
sensitivity.
Solution Readjust heater (see Sensor
Heater Adjustment).