H25-IR PRO Instruction Manual
Operation
P/N: 3015-5678 Rev 6
47
NOTE:
After changing the gas type, the screen heading on the main Measure screen or Search Screen is changed
to reflect the name of the newly selected menu option.
NOTE:
Configuration values are retained (even after power is cycled) in non-volatile memory.
NOTE:
Configuration settings under the Basic Setup menu can be thought of as “User Setup 0” and remain active
unless one of the four User Setups has been selected. See User Setups 1-4 on page 54 for more information.
NOTE:
If “Custom” is selected, the user is expected to use the External Reference feature to adjust the
instrument to his needs. For “Custom” gas configurations, the upper and lower external reference adjustment
bounds must be set by the user. Also, the user is responsible for verifying instrument response if “custom” is
used.
Table 5-8. Gas Type Menus and Selection
Menu Option
Location, Description
Gases Included
GAS TYPE
Primary List
Presented in the standard menu
(see Table 5-7 on page 46).
When equipped with the halogen
NDIR sensor this list includes the
most popular refrigerant gases; a
“CUSTOM" refrigerant option is
also shown.
Halogen NDIR
R12, R21, R22, R23, R113, R114, R123, R134a, R236fa, R245fa,
R401A, R402A, R402B, R404A, R407A R407C, R408A, R409A, R410A,
R422D, R426A, R427A, R448A, R449A, R452A, R452B, R500, R503,
R507, R508B, R513A, R514A, HFP, FA188, H1234YF, R32, H1301,
N1230, H1211, H2402, R124, R125, R227, R422a, R438a, R502,
FC72, R407F, H1234ZE, N4710, N7100, N7200, N7300, N7600
CUSTOM: The user adjusts the instrument response to a known
concentration via the “external reference" feature.
Refer to Adjustment to a Known External Leak Source
on page 81.
GAS TYPE
Secondary “Factory” List
Presented only in the Factory
Menu.
When equipped with the halogen
NDIR sensor the instrument may
be set to one of the gases in this
extended gas list. The selected
gas becomes the only gas listed in
the standard Gas Type menu; no
other gases will be listed.
R290, R600a, CO2_A, SF6
NOTE: A dedicated NDIR Sensor is required; if so equipped, the
instrument is dedicated to detect the gas shown in the GAS TYPE
menu; no other gases will be listed.
Refer to Factory Gas Type Configuration on page 84 to set one of
the gases listed above.
Summary of Contents for H25-IR PRO
Page 6: ...H25 IR PRO Instruction Manual vi P N 3015 5678 Rev 6 ...
Page 8: ...H25 IR PRO Instruction Manual viii P N 3015 5678 Rev 6 ...
Page 39: ...H25 IR PRO Instruction Manual Menu System Overview P N 3015 5678 Rev 6 29 ...
Page 109: ...H25 IR PRO Instruction Manual Maintenance P N 3015 5678 Rev 6 99 ...
Page 120: ...H25 IR PRO Instruction Manual Declaration of Conformity P N 3015 5678 Rev 6 110 ...