6.3 Error messages and troubleshooting
With every malfunction of the device check first if all cables are connected correctly.
If malfunctions have occurred that could not be corrected, please contact your
technical service representative at Bachmann electronic GmbH.
With repairs please state the following:
• Serial
number
• Type
identification
•
Short application description
•
Detailed error description
Customer service
Bachmann electronic GmbH
Tel.: +43 (0)55 22/34 97-0
Fax: +43 (0) 55 22 / 34 97-102
E-Mail: service@bachmann.info
Device does not start / no picture
Symptom
Cause
Help
Supply voltage not connected or
does not exist.
Check power cable.
Check pin assignment power
supply connection.
(
Chapter 3.2.2.6, Page OI
)
Power supply unit defective.
Return to manufacturer for repair.
Supply voltage is outside of the
permitted range.
Correct voltage range.
Incorrect display setting.
Load BIOS default settings.
(
Chapter 6.1.1, Page OI
-
Device does not start
or
shows no picture
Display defective.
Return to manufacturer for repair.
Operating system does not boot
Symptom
Cause
Help
Incorrect entry in BIOS.
Load BIOS default settings.
(
Chapter 6.1.1, Page OI
-
CF card is not addressed
No software installed.
Install software.