Ribcage Installation: Part 2 - Assembly
www.back-bone.ca | support@back-bone.ca
13
1-6 Remove M12 Ring
Pull up on the tape holding down the Ribbon connector to reveal the four screws that hold the M12 ring
in position. Depending on the date your camera or kit was purchased there is a slight variation in the
appearance but the following steps are the same for both.
Loosen each of the screws until the M12 ring comes free, but do not remove the screws. Depending on
the version of the kit used you will need either a Philips #0 screw driver or the larger of your two L-keys.
If the metal plate holding the image sensor has an open back take care not to dislodge the image sensor
as it will become loose once the M12 ring is removed. When lifting the unit hold the sensor in place
from the back with your finger.