win16pnp (System control)
DPX DPY CPX CPY
Set for MCU Mode (H,V) origin . (Normally not accessible)
Clock Adjust
Matched to upper and lower 16 MCU Outputs
*Clock Adjustment*
Select a port which needs to adjust the value for clock noise suppression
(X mark displayed).
(When the noise suppression is not done within 0~11, other causes of noise
should be checked )
Port mapping
MCU Output Patch is configured.
*Output Patch (Port mapping)*
16 red numbers corresponds to MCU OUTPUT port.
1) Select Output port( Pressing a red number place X mark on itself)
2) Port number patch ( Press a yellow number)
MCU Mode
Selection of either Horizontal or Vertical addressing mode is done
MCU initialize
Clock=ALL 3、Port(1-8)、Horizontal、Gamma=select、Contrast=2.55、
Bias=0、RGB=ALL 255
Brightness=50、Position=(0,0)
*Initialize*
①Press MCU initialize button.
②”Press 1 For initialize” is displayed and type in “1”.
③ Press MCU initialize button again
④”Initialize Done!” is displayed
Clock Position setting (Clock Noise Removal) and MCU
Output Patch
1
4