ASSEMBLY INSTRUCTIONS

A dented, rusted or damaged propane cylinder may be

hazardous and should be checked by your cylinder 

supplier. Never use a propane cylinder with a damaged 

valve connection.

The propane cylinder must be constructed and marked

in accordance with the specifications for LP gas 

cylinders of the U.S. Department of Transportation

(DOT) or the standard for cylinders, spheres and 

tubes for transportation of dangerous goods and 

commission, CAN/CSA-B339.

The cylinder must have a listed overfilling prevention 

device.

The cylinder must have a connection device compatible 

with the connection for the appliance.

The cylinder used must include a collar to protect the 

cylinder valve.

Never connect an unregulated propane cylinder to the

heater.

Attach regulator to cylinder.Complete attachment.

Install cylinder.

 Do not store a spare LP-gas cylinder under or near this appliance;

 Never fill the cylinder beyond 80 percent full;

 “Place the dust cap on the cylinder valve outlet whenever the cylinder is not

in use. Only install the type of dust cap on the cylinder valve that is provided with

the cylinder valve. Other type of caps or plugs may result in leakage of propane.”

ASSEMBLY INSTRUCTIONS

and propane Installation Code, CSA B149.1, or 

propane storage and handling code, B149.2. 

 

A dented, rusted or damaged propane cylinder 

may be hazardous and should be checked by your 

cylinder supplier. Never use a propane cylinder 

with a damaged valve connection.

The propane cylinder must be constructed and 

marked in accordance with the specifications 

for LP gas cylinders of the U.S. Department 

of Transportation (DOT) or the standard for 

cylinders,  spheres  and tubes for transportation 

of dangerous goods and commission, CAN/

CSA-B339. The cylinder must have a listed 

overfilling prevention device. The cylinder must 

have a connection device compatible with the 

connection for the appliance.

The cylinder used must include a collar to protect 

the cylinder valve.

Never connect an unregulated propane cylinder 

to the heater.

Attach regulator to cylinder. Complete attachment. 

Install cylinder.

•  Do not store a spare LP-gas cylinder under or near this appliance; 

• 

Never fill the cylinder beyond 80 percent full;

•  Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use. 

Only install the type of dust cap on the cylinder valve that is provided with the 

cylinder valve. Other type of caps or plugs may result in leakage of propane.

Summary of Contents for 554HPSQRBLK

Page 1: ...554HPSQRSTL 554HPSQRBZ 554HPSQRBLK FOR OUTDOOR USE ONLY KEEP THIS MANUAL FOR FUTURE REFERENCE TABLE OF CONTENTS Package Contents Safety Information Assembly Instructions Operation Instructions Trouble...

Page 2: ...B Damper Reflector Damper Upper Support Wireguard 1 C Upper Support D Wireguard E Glass Tube F Middle plate 4 4 1 1 G 3 H 4 I Front Panel Base Side Panel Lower Support 1 J Control box K 1 1 A B C D G...

Page 3: ...h the respect and caution demanded will reduce the possibilities of personal injury or property damage The following symbols shown below are used extensively throughout this manual Always heed these p...

Page 4: ...alteration service or maintenance can cause property damage injury or death Read the installation operation and maintenance instructions thoroughly before installing or servicing this equipment WARNIN...

Page 5: ...ignition sources including matches lighters sparks or open flames of any kind many feet away from the original leak Use only propane gas set up for vapor withdrawal Store or use propane gas in compli...

Page 6: ...NSTRUCTIONS 1 2 1 Attach 1 set wheels FF to the base J if needed 2 Attach the stability ring DD to the base J if avalable J FF DD 1 Attach 1 set wheels FF to the base J if needed 2 Attach the stabilit...

Page 7: ...supports H using the M3 16 screws AA The damper B is then assembled to the upper supports C using the M3 16 screws AA H AA J 4 B C 3 Unscrew any pre installed M3 16 screws AA first Assemble the four l...

Page 8: ...A K B Screw the winning screws washers and the winning nuts to assemble the reflector A into the damper B 5 Unscrew M3 16 4pcs screws from the bottom of the middle plate F Install an AA battery EE in...

Page 9: ...operating the heater To aid in installation place rubber ring GG on the middle plate and then install glass tube Ensure the rim of the glass tube sits firmly in the rubber ring GG D E BB ASSEMBLY INST...

Page 10: ...he control box The chain will keep the panel from falling forward while lighting operating your heater G I CC ASSEMBLY INSTRUCTIONS 9 Attach the three side panels G to the heater using the M3 16 screw...

Page 11: ...national fuel gas code ANSI Z223 1 NFPA54 natural gas and propane Installation Code CSA B149 1 or propane storage and handling code B149 2 Standard 20 lb tank ASSEMBLY INSTRUCTIONS WARNING Ensure the...

Page 12: ...Other type of caps or plugs may result in leakage of propane ASSEMBLY INSTRUCTIONS and propane Installation Code CSA B149 1 or propane storage and handling code B149 2 A dented rusted or damaged propa...

Page 13: ...cylinder valve connection disconnect reconnect and perform another leak ue to see bubbles after several attempts cylinder valve is defective and should be s place of purchase ar at any connection the...

Page 14: ...ebris Be sure any component removed during assembly or servicing is replaced and fastened prior to starting Before Lighting 1 Heater should be thoroughly inspected before each use and by a qualified s...

Page 15: ...desired temperature Heater glow is excessively uneven Heater makes popping noises Spider and insects can nest in burner or orifices This dangerous condition can damage heater and render it unsafe for...

Page 16: ...ve to a secure well ventilated location outdoors DO NOT store in a location that will exceed 50 degrees C 122 F Store heater upright in an area sheltered away from weather conditions such as rain slee...

Page 17: ...from around pilot Connection between gas valve and pilot assembly is loose Tighten connection and perform leak check Thermocouple is not operating correctly Replace thermocouple Burner won t light Pr...

Page 18: ...plate has been removed or altered Damage or failure due to improper installation improper utility connection or supply and issues resulting from improper ventilation or airflow Defects and damage due...

Reviews: