24"
48"
72"
96"
(61 cm)
(121,9 cm)
(182,9 cm)
(243,8 cm)
31
PARTS REQUIRED:
RAFTERS
BEGIN
1
Measure and mark locations for rafters.
Install (6) rafters
MJC
centered on
measurements marked.
Working inside, secure rafters to front
and back top plates with 3" screws
angled up into top plates
(Fig. A)
.
Secure side wall panels to
end-rafters with 1-1/2" nails
spaced apart equally.
The lower front edge of the rafters
overhang the wall panels by
3-11/16" (see bottom image).
Install (2)
3-1/2" x 3-1/2"
gable fi ller
panels fl ush to edges of end rafters
and fl ush to installed panels.
Secure gable fi ller panels to rafters
with (1) 1-1/2" screw.
x20
1-1/2" (3,8 cm)
3" (7,6 cm)
x20
Spaced equally
Angled up into top plate.
3"
(7,6 cm)
Screws
3"
(7,6 cm)
Screws
3"
(7,6 cm)
Screws
MJC
Gable
Filler
Gable
Filler
MEASURE FROM
INSIDE PANEL
MEASURE BETWEEN RAFTERS
2
3
Flush
to panel.
x2
3/8" x 3-1/2" x 3-1/2" (1,5 x 6,3 x 6,3 cm)
x6
MJC
2 x 4 x 53-1/2" (5,1 x 10,2 x 135,9 cm)
Fig. A
M
J
C
CENTER
on marks.
INSIDE VIEW
Top Plate
1-1/2"
(3,8 cm)
Nails
3-11/16"
(9,4 cm)