54
RAKE FLASHING
PARTS REQUIRED:
BEGIN
1
Measure, mark and cut (1)
1-1/4" x 95-1/2"
Rake Flashing into (2) 47-3/4" pieces.
Install each flashing strip flush to the back edge of roof panels and flush to side fascia.
Secure with 2" screws spaced approximately 8" apart.
Drive screws through the flashing and into the side trim framing
(Fig. F)
.
Don't over-drive screws.
47-3/4"
(121,3 cm)
Rake Flashing 15454
1-1/4" x 95-1/2" (3,2 x 242,6 cm)
x1
x11
2" (5,1 cm)
8" TYP.
(20,3 cm)
Fig. F
2"
(5,1 cm)
Screw
in peak of panel.
1/8" BIT
(3 mm)
2"
(5,1 cm)
Screws
Flush
Flush
Flush
47-3/4"
(121,3 cm)