background image

Consumption

The consumption display includes all nine digits, including leading zeroes and a decimal point  The displayed value is the sum 

of the forward flow minus the reverse flow  This display also includes indicator lines above and below the digits to provide 

the electronic equivalent of white and black number wheels on mechanical registers  The following examples show typical 

displays for three different units of measure:

DN15…DN32 Meters

DN40 and DN50 Meters

Gallons

Meter reading

100th gallon  =    1234567 89

Meter reading

to the nearest?

10th gallon  = 1234567 8

to the nearest?

10th gallon  =

12345678 9

1 gallon  =  1234567

1 gallon  =  12345678

10 gallons  = 123456

10 gallons  =

1234567

100 gallons  = 12345

100 gallons  =

123456

Typical Billing Units  

   1000 gallons  = 1234

Typical Billing Units  

   1000 gallons  =

12345

Cubic Feet

Meter reading

1000th ft

3

 =    123456 789

Meter reading

to the nearest?

100th ft

3

 = 123456 78

to the nearest?

100th ft

3

 =

1234567 89

10th ft

3

 =  123456 7

10th ft

3

 =  1234567 8

1 ft

3

 = 123456

1 ft

3

 =

1234567

 

       10 ft

3

 = 12345

   10 ft

3

 =

123456

Typical Billing Units

   100 ft

3

 = 1234

  Typical Billing Units

   100 ft

3

 =

12345

Cubic Meters

Meter reading

10000th m

3

 =    12345 6789

Meter reading

to the nearest?

1000th m

3

 = 12345 678

to the nearest?

1000th m

3

 =

1234567 89

100th m

3

 =  12345 67

100th m

3

 =  1234567 8

10th m

3

 = 12345 6

10th m

3

 =

1234567

Typical Billing Units  

       1 m

3

 = 12345

Typical Billing Units

       1 m

3

 =

123456

   10 m

3

 = 1234

  

   10 m

3

 =

12345

E-series ultrasonic meter operations

Page 11 

September 2017

ESM-UM-00255-EN-01

Summary of Contents for DN15

Page 1: ...E Series Ultrasonic Meters Cold Water Meters DN15 DN20 DN25 DN32 DN40 DN50 ESM UM 00255 EN 01 September 2017 User Manual...

Page 2: ...E Series Ultrasonic Meters Page ii September 2017 ESM UM 00255 EN 01...

Page 3: ...Meter 7 Special Fittings and Accessories 7 Installing E Series Ultrasonic Meters 7 Outdoor Installations 7 Indoor Installations 7 Installation Instructions 8 Protect Against Leakage 9 E Series Ultras...

Page 4: ...E Series Ultrasonic Meters Page iv September 2017 ESM UM 00255 EN 01...

Page 5: ...pment PRODUCT UNPACKING AND INSPECTION Upon opening the shipping container visually inspect the product and applicable accessories for any physical damage such as scratches loose or broken parts or an...

Page 6: ...al and reading Verify that a suitable electrical grounding wire is properly attached to the upstream and downstream pipe connections of the meter The grounding wire provides an alternative path for an...

Page 7: ...edded to ensure that it is not axially misaligned and that it lays evenly on the bottom of the pipe trench The backfill material covering the pipe should be placed appropriately to maintain pipe align...

Page 8: ...e nut against the meter spud end When the first threads on both the nut and the spud end coincide you will hear a slight click and feel the nut move into the starting position iii Tighten the nut by h...

Page 9: ...cape 7 Once water is flowing normally turn off the faucet E SERIES ULTRASONIC METER OPERATIONS Meter Display The Badger Meter E Series Ultrasonic meters use a nine digit Liquid Crystal Display LCD tha...

Page 10: ...feet or 100 thousand cubic meters with a resolution of 0 0001 cubic meters For DN40 and DN50 meters totalized flow displays up to 100 million gallons with a resolution of 0 1 gallons 10 million cubic...

Page 11: ...345678 10 gallons 123456 10 gallons 1234567 100 gallons 12345 100 gallons 123456 Typical Billing Units 1000 gallons 1234 Typical Billing Units 1000 gallons 12345 Cubic Feet Meter reading 1000th ft3 12...

Page 12: ...ding 7 digit reading Itron 100W 8 9 digit reading 6 digit reading 7 digit reading Itron 100W 9 digit reading 6 digit reading 7 digit reading No longer for sale 100W will transmit 9 digits through Itro...

Page 13: ...rm is sent to the endpoint NOTE No consumption data is sent to endpoint when the alarm is active Consumption data is sent to the endpoint except when Exceeding Max Flow alarm is set Reverse flow The m...

Page 14: ...o provide long term service with no maintenance The enclosure which includes the electronic meter s ultrasonic sensors battery and display is completely potted permanently sealed and non removable E S...

Page 15: ...m3 hr 4 0 gpm 1 71 m3 hr 7 5 gpm 1 71 m3 hr 7 5 gpm 1 71 m3 hr 7 5 gpm 3 2 m3 hr 14 0 gpm 4 5 m3 hr 20 gpm R Value 250 250 250 250 250 250 250 Operating Performance In the normal temperature range of...

Page 16: ...de C V Pedro Luis Ogaz n N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus...

Reviews: