AMR/AMI Output

The Ultrasonic meter is an integrated design where the electronics are housed, fully potted and permanently sealed to the  

meter housing  
Programmed to the high resolution industry standard ASCII encoder protocol, the Ultrasonic meters have the ability to 

transmit meter status indicators to ORION Cellular, Fixed Network (SE) and Migratable (ME) endpoints as part of the extended 

encoder/meter reading message  The details can also be read through an IR interface  The output protocol is indicated on the 

AMR output wire and is determined at the time of order 
The Ultrasonic meter is available with a wired lead, in-line connector or fully prewired to AMR/AMI devices 

Endpoint Reading Resolution

The reading resolution sent to the reading software is dependent on the endpoint to which the Ultrasonic meter is connected  

Readings reported from the endpoints are the left-most significant digits of the LCD reading 

Technology

High Res E-Series ADE

E-Series ADE *

E-Series RTR *

ORION Cellular

9 digit reading

6 digit reading

ORION Fixed Network (SE)

8 digit reading

6 digit reading

7 digit reading

ORION Migratable (ME)

8 digit reading

6 digit reading

7 digit reading

ORION Classic (CE)

7 digit reading

6 digit reading

7 digit reading

GALAXY

6 digit reading

6 digit reading

7 digit reading

Itron 100W

8/9 digit reading **

6 digit reading

7 digit reading

Itron 100W +

9 digit reading

6 digit reading

7 digit reading

*  No longer for sale 

** 100W will transmit 9 digits through Itron's fixed network, but will truncate to the 8 left-most significant digits for standard mobile and handheld readings 

Status Indicators

Indicators and alarms appear in the display as symbols that illuminate when the condition is active and dim when the alarm 

condition is eliminated 
All E-Series Ultrasonic meters are delivered in a storage mode so that a meter alarm is not triggered  During storage mode, 

the empty pipe shows up on the LCD display as an error message, but it will not trigger a meter alarm  The meter needs to 

sense a full pipe for 24 hours for the meter to go from storage mode to normal operation  If installed when the meter is still in 

storage mode, the meter will function as expected with the addition of also displaying “err” on the flow rate screen  The meter 

will display consumption and, if connected to AMR/AMI, will send a reading to the endpoint  When the meter is in normal 

operation, the meter alarm displays immediately upon detecting the empty pipe condition  The alarm clears immediately 

after the condition is corrected and the pipe is full  Systems that support the additional alarm conditions will be notified that 

an empty pipe condition has occurred 

E-Series® Ultrasonic Meters, Cold Water Meters

Page 12 

September 2017

ESM-UM-00255-EN-01

Summary of Contents for DN15

Page 1: ...E Series Ultrasonic Meters Cold Water Meters DN15 DN20 DN25 DN32 DN40 DN50 ESM UM 00255 EN 01 September 2017 User Manual...

Page 2: ...E Series Ultrasonic Meters Page ii September 2017 ESM UM 00255 EN 01...

Page 3: ...Meter 7 Special Fittings and Accessories 7 Installing E Series Ultrasonic Meters 7 Outdoor Installations 7 Indoor Installations 7 Installation Instructions 8 Protect Against Leakage 9 E Series Ultras...

Page 4: ...E Series Ultrasonic Meters Page iv September 2017 ESM UM 00255 EN 01...

Page 5: ...pment PRODUCT UNPACKING AND INSPECTION Upon opening the shipping container visually inspect the product and applicable accessories for any physical damage such as scratches loose or broken parts or an...

Page 6: ...al and reading Verify that a suitable electrical grounding wire is properly attached to the upstream and downstream pipe connections of the meter The grounding wire provides an alternative path for an...

Page 7: ...edded to ensure that it is not axially misaligned and that it lays evenly on the bottom of the pipe trench The backfill material covering the pipe should be placed appropriately to maintain pipe align...

Page 8: ...e nut against the meter spud end When the first threads on both the nut and the spud end coincide you will hear a slight click and feel the nut move into the starting position iii Tighten the nut by h...

Page 9: ...cape 7 Once water is flowing normally turn off the faucet E SERIES ULTRASONIC METER OPERATIONS Meter Display The Badger Meter E Series Ultrasonic meters use a nine digit Liquid Crystal Display LCD tha...

Page 10: ...feet or 100 thousand cubic meters with a resolution of 0 0001 cubic meters For DN40 and DN50 meters totalized flow displays up to 100 million gallons with a resolution of 0 1 gallons 10 million cubic...

Page 11: ...345678 10 gallons 123456 10 gallons 1234567 100 gallons 12345 100 gallons 123456 Typical Billing Units 1000 gallons 1234 Typical Billing Units 1000 gallons 12345 Cubic Feet Meter reading 1000th ft3 12...

Page 12: ...ding 7 digit reading Itron 100W 8 9 digit reading 6 digit reading 7 digit reading Itron 100W 9 digit reading 6 digit reading 7 digit reading No longer for sale 100W will transmit 9 digits through Itro...

Page 13: ...rm is sent to the endpoint NOTE No consumption data is sent to endpoint when the alarm is active Consumption data is sent to the endpoint except when Exceeding Max Flow alarm is set Reverse flow The m...

Page 14: ...o provide long term service with no maintenance The enclosure which includes the electronic meter s ultrasonic sensors battery and display is completely potted permanently sealed and non removable E S...

Page 15: ...m3 hr 4 0 gpm 1 71 m3 hr 7 5 gpm 1 71 m3 hr 7 5 gpm 1 71 m3 hr 7 5 gpm 3 2 m3 hr 14 0 gpm 4 5 m3 hr 20 gpm R Value 250 250 250 250 250 250 250 Operating Performance In the normal temperature range of...

Page 16: ...de C V Pedro Luis Ogaz n N 32 Esq Angelina N 24 Colonia Guadalupe Inn CP 01050 M xico DF M xico 52 55 5662 0882 Europe Eastern Europe Branch Office for Poland Latvia Lithuania Estonia Ukraine Belarus...

Reviews: