Transducers
Model
Construction
Cable Length
Pipe/Tubing Sizes
Pipe/Tubing
Materials
Protection
DTTC
CPVC, Ultem, Nylon cord grip
Polyethylene cable jacket; –40…194° F (–40…90° C)* 100 ft (90 m) max
0 5…2 in (12…50 mm)
Carbon steel,
stainless steel,
copper and
plastic
NEMA 6/IP67
DTTR
PBT glass filled, Ultem®, Nylon cord grip
PVC cable jacket; –40…250° F (–40…121° C)
300 ft (90 m) max
2 5…10 in (DN65…DN250)
NEMA 6/IP67
DTTN
CPVC, Ultem, Nylon cord grip
Polyethylene cable jacket; –40…194° F (–40…90° C)
300 ft (90 m) max
2 5…10 in (DN65…DN250)
NEMA 6/IP67
DTTN
Submersible
CPVC, Ultem, Nylon cord grip
Polyethylene cable jacket; –40…194° F (–40…90° C)
300 ft (90 m) max
2 5…10 in (DN65…DN250)
NEMA 6P/IP68
Easy Rail
(DTTJ/K)
PBT glass filled, Ultem®, Nylon cord grip
PVC cable jacket; –40…250° F (–40…121° C)
100 ft (30 m) max
2 5…6 in (DN65…DN150)
2 5…10 in (DN65…DN250)
NEMA 6/IP67
* DTTC integral mount temperature is limited by the transmitter temperature rating
Configuration Software
The flow meter can be programmed and configured with the SoloCUE Flow Device Manager software The software also
has troubleshooting tools for diagnosing and correcting installation problems English, French, German, Italian and Spanish
languages can be selected in the software
SoloCUE
Used to configure and troubleshoot flow meter Software is compatible with Windows® 7 SP1 or newer
Figure 35: SoloCUE setup screen
Figure 6: SoloCUE diagnostics screeen
Additional Parts Required for Configuration
Part Number
Description
RC820648
USB Type A to mini B software cable (shielded to minimize noise)
Specifications
Page 39
May 2021
TTM-UM-02537-EN-06