Figure 15:  Default pulse weights

Meter Size

Measurement Resolution

Scaled (pulse/unit)

Unscaled (pulse/unit)

Analog Output

gal

ft3

m3

gal

ft3

m3

20 mA Set point 

(gpm)

5/8 x 3/4 in.

1

10

100

50

500

 20,000 

30

OUTPUTS

Encoder Output

Programmed to the industry standard ASCII encoder protocol, E-Series Ultrasonic meters have the ability to transmit meter 

status indicators to ORION Cellular, Fixed Network (SE) and Migratable (ME) endpoints as part of the extended encoder/meter 

reading message  The details can also be read through an IR interface  

Endpoint Reading Resolution

The standard electronic encoder output resolution of the E-Series Ultrasonic meter is 9 digits  Though the meter output 

is 9-digit resolution, the reading resolution sent to the reading software is dependent on the endpoint that the meter is 

connected to  Readings reported from the endpoints are the left-most significant digits of the encoder reading  

Endpoint Technology

Reading Resolution Reported to Reading Software

ORION Cellular

9-digit reading, plus the extended message capability

ORION Migratable (ME)/Fixed Network (SE)

8-digit reading, plus the extended message capability 

ORION Classic (CE)

7-digit reading

GALAXY

6-digit reading

Wire Connections

The E-Series Ultrasonic meter is available with a connector for easy connection and installation to AMR/AMI endpoints  It is 

also available with a flying lead for field splice connection  The in-line connector is recommended for pit applications  

Dual Output

The E-Series Ultrasonic meter is also available with dual outputs  The following dual output options are available: 

•  Encoder and encoder

•  Encoder and 4-20 mA

•  Encoder and scaled/unscaled

•  Scaled/unscaled and 4-20 mA

Scaled Output

•  Scaled output is a switch closure output defined as: 

red

 wire = positive, 

black

 wire = negative  

•  Scaled output from the register has a default resolution 1/10th of the register test circle (resolution may vary in  

some cases) 

•  The nominal pulse output width is programmable from 30…100 msec  
•  This pulse output is compatible with most totalizers and batch controllers  

Unscaled Output

•  Unscaled output is a switch closure output defined as: 

green

 wire = positive, 

black

 wire = negative

•  This pulse output is compatible with most totalizers and batch controllers  

Outputs

Page 12 

May 2021

Summary of Contents for E G2 Series

Page 1: ...E Series G2 Ultrasonic Meter Lead Free Bronze Alloy 5 8 x 3 4 inch ESM UM 03099 EN 02 May 2021 User Manual...

Page 2: ...gs and Accessories 5 Removing a Meter 5 Meter Operating Modes 6 Installation 6 Outdoor Installations 6 Indoor Installations 6 Pre Installation 7 Installation Instructions 7 Operations 9 Display 9 Acti...

Page 3: ...optional integrated pressure sensor Applications E Series Ultrasonic meters measure potable cold water in residential applications The meter is also ideal for non potable reclaimed irrigation water a...

Page 4: ...ure 2 Water Pressure and Temperature sensors selection 3 Select the Water Pressure and or Water Temperature check boxes to turn on reporting for the temperature and or pressure meter sensors 4 Select...

Page 5: ...ble use in reshipment or storage Visually inspect the meter and applicable accessory devices for any signs of damage such as scratches loose or broken parts or other physical damage that may have occu...

Page 6: ...ter box is properly bedded so that it is not axially misaligned and that it lays evenly on the bottom of the pipe trench Place the backfill material covering the pipe appropriately to maintain pipe al...

Page 7: ...of the meter Externally weighted check valves and pressure reducing devices should not be located in proximity of the meter Installation Instructions 1 Begin at this step when cutting in for new serv...

Page 8: ...r appropriate for the meter size the better Take caution when opening the inlet valve to avoid damage to the pressure sensor due to extreme water hammer 13 Slowly open the outlet valve until air is ou...

Page 9: ...e alarms and temperature and pressure data are sent as part of the encoder message and surfaced in BEACON AMA when meter is used with ORION Cellular LTE M LTE MS or LTE endpoints Activating the Displa...

Page 10: ...h ft3 123456 78 10 ft3 123456 7 1 ft3 123456 10 ft3 12345 Typical Billing Units 100 ft3 1234 Cubic Meters Meter reading to the nearest 10000th m3 12345 6789 1000th m3 12345 678 100th m3 12345 67 10th...

Page 11: ...s stored in this position until reported to the endpoint Up to 15 min with ORION Cellular Position 1 Position 2 Position 3 Figure 10 Alarm and operating mode screen in transition mode Up to 1 hr with...

Page 12: ...rted to Reading Software ORION Cellular 9 digit reading plus the extended message capability ORION Migratable ME Fixed Network SE 8 digit reading plus the extended message capability ORION Classic CE...

Page 13: ...Encoder and Scaled Unscaled RED Scaled Pulse GREEN Unscaled Pulse BLACK Ground Encoder cable with in line connector Scaled unscaled cable with flying lead RED Scaled Pulse GREEN Unscaled Pulse BLACK G...

Page 14: ...ally filled pipe Last known good read is displayed If the meter is active and detects an empty pipe water temperature displays ErrF or ErrC If meter is in storage mode and detects an empty pipe water...

Page 15: ...lert Measurement error 004 End of life 013 Empty pipe Temperature Reverse flow 100 Pressure 008 No usage 018 No usage Reverse flow 101 Empty pipe Pressure 009 Empty pipe No usage 020 Suspected leak 14...

Page 16: ...ing permanently sealed electronic LCD digits are 0 28 in 7 mm high Register Display Total consumption nine digits Unit of measure factory programmed for gallons cubic feet and cubic meters Rate of flo...

Reviews: