ESM-UM-03099-EN-02

BEACON FIRST TIME SETUP

For meters connected to ORION Cellular LTE-M, LTE-MS or LTE endpoints, perform these steps to make sure the E-Series 

Ultrasonic meter sensor information is accessible in BEACON  
1   In BEACON, select the 

Assets

 tab  Then select 

Utility Settings

 from the menu on the left 

Figure 1:  BEACON Assets

2   On the Utility Settings page, scroll down to the 

Monitor Page Filters 

section and find the 

Sensors

 section  

Figure 2:  Water Pressure and Temperature sensors selection

3   Select the 

Water Pressure

 and/or 

Water Temperature 

check boxes to turn on reporting for the temperature and/or 

pressure meter sensors 

4   Select 

Update Utility

 at the bottom of the page  

to save your changes  

Figure 3:  Save changes

5   Select the 

At A Glance

 tab and click 

Add/Remove

 on the right side of the page below the main tabs menu 

6   On the window that opens, select 

Add

 for 

Water Pressure Health

 and 

Water Temperature Health

  Then select 

Done

 

Water Pressure Health

 and 

Water

 

Temperature

 

Health

 modules now display on the 

At A Glance

 page 

 

Setup is complete 

Requirements

Page 4 

May 2021

Summary of Contents for E G2 Series

Page 1: ...E Series G2 Ultrasonic Meter Lead Free Bronze Alloy 5 8 x 3 4 inch ESM UM 03099 EN 02 May 2021 User Manual...

Page 2: ...gs and Accessories 5 Removing a Meter 5 Meter Operating Modes 6 Installation 6 Outdoor Installations 6 Indoor Installations 6 Pre Installation 7 Installation Instructions 7 Operations 9 Display 9 Acti...

Page 3: ...optional integrated pressure sensor Applications E Series Ultrasonic meters measure potable cold water in residential applications The meter is also ideal for non potable reclaimed irrigation water a...

Page 4: ...ure 2 Water Pressure and Temperature sensors selection 3 Select the Water Pressure and or Water Temperature check boxes to turn on reporting for the temperature and or pressure meter sensors 4 Select...

Page 5: ...ble use in reshipment or storage Visually inspect the meter and applicable accessory devices for any signs of damage such as scratches loose or broken parts or other physical damage that may have occu...

Page 6: ...ter box is properly bedded so that it is not axially misaligned and that it lays evenly on the bottom of the pipe trench Place the backfill material covering the pipe appropriately to maintain pipe al...

Page 7: ...of the meter Externally weighted check valves and pressure reducing devices should not be located in proximity of the meter Installation Instructions 1 Begin at this step when cutting in for new serv...

Page 8: ...r appropriate for the meter size the better Take caution when opening the inlet valve to avoid damage to the pressure sensor due to extreme water hammer 13 Slowly open the outlet valve until air is ou...

Page 9: ...e alarms and temperature and pressure data are sent as part of the encoder message and surfaced in BEACON AMA when meter is used with ORION Cellular LTE M LTE MS or LTE endpoints Activating the Displa...

Page 10: ...h ft3 123456 78 10 ft3 123456 7 1 ft3 123456 10 ft3 12345 Typical Billing Units 100 ft3 1234 Cubic Meters Meter reading to the nearest 10000th m3 12345 6789 1000th m3 12345 678 100th m3 12345 67 10th...

Page 11: ...s stored in this position until reported to the endpoint Up to 15 min with ORION Cellular Position 1 Position 2 Position 3 Figure 10 Alarm and operating mode screen in transition mode Up to 1 hr with...

Page 12: ...rted to Reading Software ORION Cellular 9 digit reading plus the extended message capability ORION Migratable ME Fixed Network SE 8 digit reading plus the extended message capability ORION Classic CE...

Page 13: ...Encoder and Scaled Unscaled RED Scaled Pulse GREEN Unscaled Pulse BLACK Ground Encoder cable with in line connector Scaled unscaled cable with flying lead RED Scaled Pulse GREEN Unscaled Pulse BLACK G...

Page 14: ...ally filled pipe Last known good read is displayed If the meter is active and detects an empty pipe water temperature displays ErrF or ErrC If meter is in storage mode and detects an empty pipe water...

Page 15: ...lert Measurement error 004 End of life 013 Empty pipe Temperature Reverse flow 100 Pressure 008 No usage 018 No usage Reverse flow 101 Empty pipe Pressure 009 Empty pipe No usage 020 Suspected leak 14...

Page 16: ...ing permanently sealed electronic LCD digits are 0 28 in 7 mm high Register Display Total consumption nine digits Unit of measure factory programmed for gallons cubic feet and cubic meters Rate of flo...

Reviews: