ELECTRICAL / NETWORK INSTALLATIONS
Access to Power
•
The gateway requires access to power and can use either a 120V AC grounded outlet for use with the AC-to-DC
power supply and power cord (66528-003), or a DC power source to be used with the DC power source cable with
308 in-line connector . For a gateway with a LAN PoE configuration, a Power over Ethernet connection is required .
•
Outlet and enclosure (if required) should be mounted for easy accessibility by authorized utility personnel at the
installation site .
•
Consult appropriate electrical, building and industry codes, regulations and standards for accepted installation
practices for use of the AC-to-DC power supply and outlet in environmentally controlled indoor locations .
Use of a NEMA 4 Enclosure
AC-to-DC power supply used outdoors or in a non-environmentally controlled indoor location requires a customer-supplied
NEMA 4 enclosure, or equivalent, be installed in accordance with appropriate electrical codes, building codes, industry codes,
regulations and standards .
CDMA or GPRS Recommended Installation
AC to DC Power Supply with
308 In-line Connector End and
Power Cord (supplied)
120VAC
Grounded Outlet
(customer
supplied)
Power Supply Cable with
308 In-line Connector
Power Cable with
308 In-line Connector
(supplied)
Figure 17: CDMA or GPRS connection with AC power source (*Shown with NEMA 4 enclosure)
*An enclosure may be recommended but is not included .
If NEMA 4 enclosure or equivalent is required, the minimum enclosure size is 12" x 10" x 6" (H x W x D) .