Register operation
October 2019
AC_ILR_BA_02_1632
Page 3
2.
REGISTER OPERATION
The following describes register operation and program settings for the industrial oval gear series registers: Industrial
Standard (ILR 700 / 701 / 701T), Pulse and Analog (750 / 750T).
The register display consists of two rows of seven-segment digits, status, unit of measures, flow rate, and battery indicators.
Operating function settings and programming are provided using the
TOTAL
and
RESET
buttons.
Register display and button
2.1
Normal operation
(for models ILR 7XX)
To enter normal operation mode - when the screen is blank after exiting programming mode, or upon initial use, press either
the
TOTAL
or
RESET
button once.
2.2
Status
The status indicators are
RESET
and
TOTAL
.
2.3
Totalizers
The top row of indicators is the batch totalizer. This totalizer displays the cumulative volume of flow through the meter with
six digits. The batch totalizer totalizes in selected units of measure.
To reset the batch totalizer, after 2 seconds of no flow, press and release the
RESET
button.
The bottom row of indicators displays the resettable totalizer with five digits or the five least significant digits of the non-
resettable totalizer.
RESET
and
TOTAL
is indicated when the resettable total is displayed in the five-digit lower row. Only
TOTAL
is indicated when the non-resettable total is displayed.
To toggle between the non-resettable totalizer and the resettable totalizer, press and release the
TOTAL
button.
To reset the resettable totalizer, press and hold the TOTAL button and then press and release the
RESET
button.
To display 11-digit non-resettable totalizer, while the non-resettable total is displayed, press and hold the TOTAL
button for seconds. The top row displays the 6 most significant digits; the bottom row displays five least-significant
digits.
NOTE:
The non-resettable totalizer normally displays 5 least-significant digits.