Flow meter ModBus
®
register table 2017-06-29, Version 2.00
Page 41/43
UF_iS4000_BA_02_1811
0x0414
float
Admin
OPENCHANNEL_
COEFFICIENT_ACTUALUNIT
Open channel calibration
0x0416
float
Admin
OPENCHANNEL_
WIDTH_ACTUALUNIT
Open channel calibration
0x0418
float
Admin
OPENCHANNEL_
RADIUS_ACTUALUNIT
Open channel calibration
0x041A float
Admin
OPENCHANNEL_
WATERLEVELMAXIMUM_
ACTUALUNIT
Open channel calibration
0x041C float
Admin
OPENCHANNEL_
SURFACEROUGHNESS_
ACTUALUNIT
Open channel calibration
iSonic conversation table
Address
Registers
Rights
Read
Write
Name
Note
0x0500
Float, Float
Admin
Yes
Yes
Conversion Table
Point 0
Water Level [m],
Volume [m³] or Flow[m³/s]
…
…
0x08FC
Float, Float
Admin
Yes
Yes
Conversion Table
Point 255
Points in conversion table have to be sorted in ascending order (higher address
higher water level value).
Table can be shorter. First unused point has to contain NAN value
Rights
1 User
2 Service
3 Admin
4 Factory