Power connections
Page 13/47
MID_M1000_BA_02_1802
BA
17
MI
D
weiß (45)
braun (46)
pink (40)
schwarz (44)
schwarz (44)
gelb/grün (13)
gelb (12)
grün (11)
5 bis 300 m
grün (11)
gelb (12)
pink (40)
weiß (45)
braun (46)
schwarz (44)
schwarz (44)
gelb/grün (13)
5 to 50 m
pink
4.2.1 Signal cable specification
Note:
•
Only use signal cables delivered by Badger Meter or corresponding
cable in accordance with the following specification.
•
Take max. signal cable length between detector and amplifier into
account (keep distance as low as possible).
Distance
With electrode idle
Loop resistance
0 – 50 m
3 x (2 x 0,25 mm²)
=< 160
Ω
/km
PVC cable with pair and total shield
Capacity: wire/wire < 120 nF/km, wire/shield < 160 nF/km
Temperature range –30 °C to +70 °C
Maximum cable length at different fluid temperatures
0
25
50
75
100
125
150
175
200
225
250
275
300
0
25
50
75
100
125
150
175
Temperature [°C]
C
abl
e
le
ngt
h
[m
]
0,25 mm²
0,5 mm²
0,75 mm²
B
A
17M
ID
white
white
brown
brown
black
black
black
black
yellow/green (13)
yellow/green (13)
yellow (12)
yellow (12)
green (11)
green (11)