Power connections
Page 15/47
MID_M1000_BA_02_1802
4.3.1 In- and output cable connection
For the normal I/Os use shielded cables. Connect the shield of the cable to one of the
grounding screw. Recommended cable LiYCY size min. 0,14 mm².
Solid State Output
In case the second cable gland is used for the normal I/Os, use one cable and cable
gland for the power supply and Solid Satate relay. Recommended cable size min.
0,75 mm².
Caution:
•
Use separate cable inlets for cables connected to the Solid State Relay
output and cables connected to the other input/outputs.
•
In multiphase nets solid state relay should handle only the same phase
which is used for powering the meter.
Summary of Contents for ModMAG M1000
Page 46: ...Program structure Page 44 47 MID_M1000_BA_02_1802 8 Program structure ...
Page 47: ...Program structure Page 45 47 MID_M1000_BA_02_1802 ...
Page 50: ......