Programming
Page 17/47
MID_M1000_BA_02_1802
5.1 Main menu
The following menu items are available to you in the main menu:
•
Meter setup
•
Measurements
•
Inputs and outputs
•
Totalizer reset
•
Communication
•
Miscellaneous
•
Information
•
Pin
5.1.1 Meter setup
Calibration
Diameter
This figure is used for setting pipe’s diameter
(size). Several sizes DN 6 to DN 500 can be set.
Note: Pipe diameter is set at the factory.
Changes of size have an impact on meter’s
accuracy.
Detector Factor
This parameter is set at the factory. This factor
compensates for accuracy error as a result of the
installed detector. If accuracy adjustment of the
meter is required, please refer to the scale factor.
In the event the amplifier is replaced, this para-
meter must be reprogrammed with the original
detector factor.
Detector Zero
This parameter is set at the factory. This factor
compensates for accuracy error as a result of the
installed detector. If accuracy adjustment of the
meter is required, please refer to the scale factor.
Amplifier Factor
Electronic calibration factor
Read only
Coil Current
Coil current row the detector
Read only
Scale Factor
Changing the scale factor lets you adjust the meter’s accuracy
without disturbing parameters set by the factory. You can tune the
meter to meet changing application requirements in a range of ±5%
(0,95 to 1,05)