UniMod LTE 

 

17 

7.2 

Parity Error (7E1) 

Depending  on  certain  circumstances  (software  configuration,  hardware 
configuration of the PC, connection of the modem to the PC, operating sys-
tem,...) the communication software of your application might issue a mes-
sage like: wrong parity. In the most cases a switch of the UniMod LTE data 
format  from  "7E1"  to  "8N1"  is  able  to  bring  fast  and  easy  help.  Using  this 
configuration data retrieval from most meters is possible in the format "7E1" 
and "8N1".  

If there are any further questions we are happy to help you. 

 

Summary of Contents for UniMod LTE

Page 1: ...UniMod LTE Modem User Manual E101006219063 Baer Energie Messtechnik GmbH Siemensstr 3 D 90766 F rth Germany Phone 49 911 970590 Fax 49 911 9705950 Internet www baer gmbh com...

Page 2: ...H preserve the right to modify and improve the software product described in this docu ment Specifications and other information contained in this document can change without prior notice This documen...

Page 3: ...y Error 7E1 17 8 Additional Functions 18 8 1 Temporary Baud Rate Switching 18 8 2 Cyclic Reset 19 8 3 Password Protection 19 8 4 SIM Card 19 8 5 More PLMNs in Radio Network 20 8 6 Client Mode IPT Brid...

Page 4: ...UniMod LTE 4...

Page 5: ...ements The UniMod LTE can be used in LTE Long Term Evolution 4G fourth generation network with an arbitrary number of providers It requires how ever the infrastructure for operating mobile An existing...

Page 6: ...parent and should be returned for testing to an authorised service centre internal damage possible Devices must never be cleaned with running water or high pressure devic es Water can cause short circ...

Page 7: ...5VAC to 265VAC 50 60Hz or 60VDC to 375VDC use an external protection fuse e g circuit breakers B6A alternative with additional board 10VDC to 36VDC 0 8A Attention NEVER remove the interface modules or...

Page 8: ...870 M Bus Modbus SCTM LSV1 trans parent reading The UniMod LTE has an internal on board RS485 2 wires interface Using the UniModSet program the user can determine the functionality of the RS485 interf...

Page 9: ...ax or passive if the 20mA interface is active it must be operated either with a load or its terminals must be short cut RS232 RxD TxD CTS RTS GND RS485 2 wires RS485 4 wires M Bus active for max 20 de...

Page 10: ...reader 1 When the holder is closed you must first slide the holder down wards in the arrow s direction OPEN 2 After release you can open the lid and insert the Micro SIM Card as shown in the picture...

Page 11: ...the radio signal strength 25 50 75 100 All four LEDs flash regularly no or faulty SIM Card inserted 2G The modem is logged in GPRS network 3G The modem is logged in UMTS network 4G The modem is logged...

Page 12: ...T error in case of a login error the IPT LED flashes continuously 7 Programming the Modem Before installing the modem it has to be programmed in order to meet the demands The baud rate and data format...

Page 13: ...SB port at the PC and wait for confirma tion both LEDs flash shortly Then wait until the USB port is configured cor rectly message Install device driver software Note Older versions of Windows Windows...

Page 14: ...This COM can then be used in UniModSet Now you have to select the new COM interface in the parameterization software UniModSet After programming switch off the UniMod LTE remove the parameteriza tion...

Page 15: ...the picture Insert the 7 pole plug of the parameteri zation adapter instead of the interface module The notch must point in direction to the top Then connect the 25 pole plug RS232 to the PC port At...

Page 16: ...or 4G radio network Start the UniModSet software Read the equipment configuration Adjust the parameter Hint Mind to set the functionality of the internal RS485 interface correctly Write the configurat...

Page 17: ...ting sys tem the communication software of your application might issue a mes sage like wrong parity In the most cases a switch of the UniMod LTE data format from 7E1 to 8N1 is able to bring fast and...

Page 18: ...modem switches after the character is recognized without acknowledgement These parameters are possible Baud rate Data format x 0 300 Baud 1 600 Baud 2 1200 Baud 3 2400 Baud 4 4800 Baud 5 9600 Baud 6...

Page 19: ...Protection It is also possible to activate the password for remote programming Re mote Control Default password is modem1 Please note that passwords are case sensitive 8 4 SIM Card The internal CPU c...

Page 20: ...le Network after logging on to the radio network Thus it is possible to pre program the modem for dif ferent SIM Cards When the field PLMN Code is empty the UniMod LTE uses the first avail able mobile...

Page 21: ...nnection In addition a dynamic pause for logging on to the radio network 1 4 16 64 minutes to 24 hours pause in case of error can be activated If the optional TLS encryption is activated the modem nee...

Page 22: ...s for firewall network security system that controls incoming net work traffic Examples Firewall IP 0 0 0 0 and network mask 0 0 0 0 invalid firewall connec tion to all IP addresses is possible accept...

Page 23: ...ce Note activate for correct display Note use only for testing deactivate please this function after the tests 8 9 TLS Encryption TLS encryption is only possible in the client mode with IPT Bridge Uni...

Page 24: ...re move or disable the SIM Card in the modem Radio When doing a firmware update remotely via radio connection the data for mat must be set to 8N1 set option Read see picture below Note For TCP IP conn...

Page 25: ...confirmation prompt After OK the firmware will be up dated The process is visualized with the aid of a progress display Duration of transmission depending on the set baud rate Local ca 60 seconds 384...

Page 26: ...20mA current loop active can supply 4 meter max or pas sive RS485 2 wires RS485 4 wires M Bus active can supply 20 devices max Display 14 LEDs GSM 4 radio signal strength 2G 3G 4G TLS IPT Rx Tx INF a...

Page 27: ...face module as ordered Standard antenna magnetic foot antenna with SMA m cable 3m RG174 Operation manual Accessories Parameterization adapter with USB port 12823 Antenna for special purposes Additiona...

Page 28: ...les their component side must be at the left side and wired according the picture In the following sketch the com ponents are at the left side UniMod LTE Interface modules RS232 20mA active 20mA pas R...

Page 29: ...UniMod LTE 29 11 Terminal Block Optional power supply 12VDC 24VDC Terminal Voltage 1 10VDC to 36VDC 2 0VDC GND...

Page 30: ...UniMod LTE 30 12 Dimensions Wall mounted housing according to DIN 43861 2 Option 9141...

Page 31: ...43861 2 complies with the following EU directives 2014 53 EU Radio Equipment Directive RED 2011 65 EU Hazardous Substances and conforms to the following harmonized standards Reference number Date of...

Page 32: ...UniMod LTE Subject to change without notice...

Reviews: