Configuration Commands
When using these commands, remember these points:
1. Commands may be entered in upper or lower case.
2. To execute a command always hit the <
Enter
> key.
3. The factory default option is shown in brackets [BAI-10].
Configuration
Command:
CFG
Purpose: Displays the current configuration of the BA-440 DualBeam.
Options: none
Example:
CFG
Result:
Note: The actual configuration may be different
depending on how the BA-440 DualBeam is set.
Configuration for BA-440 DualBeam Barcode Reader
Serial Number XXXXXXX-XX
Gain Channel Both
Label Format BAI-10
Vehicle Detect Mode Scan
Wiegand Bits 26
Wiegand Pulse Width 7
Wiegand Pulse Interval 7
Verify Vehicle Number Off
Minimum Reads 1
Communication Baud Rate 9600
Communication Parameters N81
Good Read Message "~F ~L~r~n"
Scan Detect Timeout 1000 ms
Good Read Pulse 1000 ms
Beeper Time 200 ms
Facility Code Shift Off