background image

 

11 

 

Figure 3-6 Insert line card into Connector 

 

7.

  Crimping the cable using crimper, as shown in Figure 3-7.

 

Figure 3-7 Crimping connector 

 

8.  Impact the metal part of the shielded connector tail with the metal net shielded layer 

of the Ethernet cable using nipper pliers, as shown in Figure 3-8. 

Figure 3-8 Impact the connector with cable shield layer 

 

Summary of Contents for CW0100

Page 1: ...All rights reserved BaiCells Technologies Co Ltd BaiCells CW0100 CPE Installation Guide V1 0...

Page 2: ...d in any form or means without the prior written consent of BaiCells Disclaimer This specification is preliminary and is subject to change at any time without notice BaiCells assumes no responsibility...

Page 3: ...2 LED Indicators 6 2 3 RF Specifications 6 2 4 Install on Pole 7 2 5 Install on Wall 8 2 6 3 Wire Connection 9 Make Ethernet Cable Connector 9 3 1 Connect Ethernet Cable 13 3 2 Power On 14 3 3 Lightn...

Page 4: ...yer 9 Figure 3 3 Cut off the aluminum foil layer of twisted pair 10 Figure 3 4 Color Order 10 Figure 3 5 Insert the twisted pair core into line card 10 Figure 3 6 Insert line card into Connector 11 Fi...

Page 5: ...Contents of Table Table 2 1 CW0100 Interface and button 5 Table 2 2 LED Indicators 6 Table 2 3 RF Specification 6 Table 3 1 Lightning Protection Demand of Cable 15...

Page 6: ...Check whether the material in the box is consistent with Shipping List and is in good condition and undamaged Note During the unpacking if the outer package is damaged or soaked stop unpacking and fin...

Page 7: ...installation site Plastic tie Grounding wire Installation Tools 1 3 The following tools are needed during the installation Standing wave measuring instrument Nipper pliers Diagonal pliers Pincer plier...

Page 8: ...g to Reconnaissance Report check whether the external environment of installation site is ready Safety Protection 1 5 Construction personnel must conform to Construction Safety Specification wearing s...

Page 9: ...igure 2 1 Appearance of CW0100 CW0100 CPE support installing on pole or installing on wall The following introduces the two ways separately Caution The direction of CPE cable exit end must be down Int...

Page 10: ...n Connected the signal is weak Two LED Steady On Connected the signal is medium Three LED Steady On Connected the signal is strong LAN Eth Indication Green OFF Ethernet connection is not established S...

Page 11: ...0mm and diameter is 25mm to 45mm as the mounting bracket Iron on tower If CPE is installed on iron tower you need to choose vertical direction angle iron as the mounting bracket The length is about 25...

Page 12: ...talls on wall the installation method is as follows On the wall fix two big head screw which distance is 52mm and then hang the CPE on the big head screw Figure 2 4 Mounting Hole of Install on Wall Fa...

Page 13: ...strip the outer Jacket of the twisted pair about 30mm using crimping tool which is shown in Figure 3 1 Figure 3 1 Strip Shielded Twisted Pair 2 Separate the metal net wire of cable and aluminum foil l...

Page 14: ...4 Color Order 5 Insert the eight wires into the line card according to the color order shorten them to a suitable length about 12 mm using diagonal pliers as shown in Figure 3 5 Figure 3 5 Insert the...

Page 15: ...crimper as shown in Figure 3 7 Figure 3 7 Crimping connector 8 Impact the metal part of the shielded connector tail with the metal net shielded layer of the Ethernet cable using nipper pliers as show...

Page 16: ...fter the completion of shielded connector making as shown in Figure 3 10 Repeat all the steps and wire color on the other end of the cable Figure 3 10 Completion of shielded connector 11 Test whether...

Page 17: ...ny signal indicator is red or yellow it indicates that there is circuit break or bad contact You need to make a new connector again Connect Ethernet Cable 3 2 1 Connect the shielded cable to WAN inter...

Page 18: ...0 outdoor CPE is powered with POE CPE provides standard POE power interface conformed to IEEE 802 3af standard The 4 5 7 8 wire have direct current Before power on test whether there is voltage output...

Page 19: ...leeve It is highly recommended that the distance is as nearest as possible between the two equipment connected by Ethernet cable avoiding the cable hanging in the air According to the wiring environme...

Page 20: ...ng CPE IP address normal CPE Configuration Check 4 3 Log in the WebUI of CPE check whether the software version is correct whether the LTE mode is enabled and whether WAN interface and LAN interface a...

Page 21: ...frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur...

Page 22: ...s de licence L exploitation est autoris e aux deux conditions suivantes 1 l appareil ne doit pas produire de brouillage et 2 l utilisateur de l appareil doit accepter tout brouillage radio lectrique s...

Page 23: ...TE network CPE receive download signal weak If external antenna is used check whether antenna feed system have connected normal The standing wave measuring can be used Check whether the internal coaxi...