17
4.3 Wall Installation
The steps for installing a Neutrino eNB on a wall are the same as when installing it on a ceiling,
as covered in
section 4.2
Ceiling Installation, with the exception that you will need to adjust
the direction of the arrow on the bracket according to the wall placement. Be sure the 3 holes
for the bolts are in the correct position.
Proceed to section 4.4, next.
4.4 Connect Cables
Connect the power adaptor to the unit and outlet, as explained in
section 3
Verify Basic
Operation. Do not power on the unit yet.
Connect an Ethernet cable to the WAN port on the unit; the other end connects to the
backhaul device.
4.5 Power on
Power on the Neutrino eNB. It may take a minute or two for the LEDs to provide status
information. Refer to Table 2-3 LED Status to ensure the PWR LED is showing a steady white
light. The other LED will be more accurate after you complete the basic configuration, which
is discussed in
section 5
Configuration.
4.6 Check eNB Status in Software
The Baicells eNBs are designed to be plug-and-play and, therefore, arrive with many
parameters pre-configured using default values. You will need to connect a computer to the
LAN port using an Ethernet cable to ensure the eNB status is reported as active before you
continue with the installation.
4.6.1
Computer Requirements
The client computer you use to interface with the LAN port on the eNB must meet the
following minimum requirements shown in Table 4-1.
Table 4-1: Computer Requirements
Item
Description
CPU
Intel Core 1GHz or higher
Memory
> 2G RAM
Hard Disk
> 100 MB space available
Operating system
Microsoft: Windows XP, Windows Vista, or Windows7
Mac: MacOSX10.5 or later
Screen resolution > 1024 x 768
Browser
Chrome 6 or higher
Summary of Contents for Neutrino-224
Page 1: ...Neutrino 224 Indoor 2x125mW FDD TDD eNodeB Installation Guide December 2018 Version 1 7...
Page 20: ...20 Figure 4 7 FDD eNB GUI Home Page Figure 4 8 TDD eNB GUI Home Page...
Page 47: ...47 Figure 5 24 LTE Neigh Freq Settings 1 of 2 Figure 5 25 LTE Neigh Freq Settings 2 of 2...
Page 64: ...64 Figure 5 38 Cell ReSelection Parameter Figure 5 39 Additional Measurement Parameter...