20
20
Attaching the Saw Bow Cover Guard
Using the (2) hex bolts, lock washers, and flat
washers provided, attach the bow cover guard.
Coolant Tank Preparation
Use a 20:1 (water to coolant) solution to increase cutting
efficiency and prolong blade life.
1. Disconnect machine from the power source.
2. Remove the coolant return hose from the drain pan fitting
and the strainer basket.
3. Slide the tank out from the lower compartment.
4. Remove the strainer basket and fill the tank to 80%
capacity with coolant.
5. Replace the strainer basket and return the tank assembly back
into the base.
6. Place the drain hose into the basket and connect to the drain
fitting.
7. Assemble the bolt to the drain screen as shown and set over
the drain hole.