19
19
AA Coolant Pump Selector Switch
Starts the coolant flow for cutting.
AB Reverse Button
Reverses the spindle rotation for tapping only.
AC Digital Indicator
Displays the rate of spindle rotation in RPM.
AD Spindle Speed Knob
Changes the speed of spindle rotation.
AE Drilling / Tapping Selector Switch
Selects the mode of operation: drilling or tapping.
AF Start Button
Starts the spindle motor. A 10 sec. wait is
required before a machine restart or the machine
will not start.
AG Stop Button
Stops the spindle motor.
AH Emergency Stop Button
Stops all machine functions. Turn the switch
clockwise (cw) to reset the switch.
DIGITAL INDICATOR
RPM
0
l
150-3000RPM
0
l
SPINDLE SPEED
AD
AC
AF
AG
AA
AE
AB
AH
Summary of Contents for DP-1000VS
Page 19: ...16 16 OVERALL DIMENSIONS ...
Page 20: ...17 17 GETTING TO KNOW YOUR MACHINE Q F P J B C A G H I L M E F D N O K R ...
Page 35: ...32 32 A6 2 A6 3 A6 1 A6 4 A8 1 A8 2 A5 A5 1 A33 1 A19 1 A33 ...
Page 39: ...36 36 BASE COLUMN AND TABLE PARTS DIAGRAM B1 B2 B11 B10 B9 B10 1 ...
Page 40: ...37 37 B3 B4 B6 1 B6 B5 1 B5 2 B8 B8 1 B12 B13 B16 B15 B14 ...
Page 44: ...41 41 COOLANT PUMP ASSEMBLY PARTS DIAGRAM ...
Page 46: ...43 43 CONTROL PANEL PARTS DIAGRAM ...
Page 48: ...45 45 CHUCK GUARD PART DIAGRAM ...