46
46
Trouble
Probable Cause
Remedy
Machine will not
start/restart or
repeatedly trips circuit
breaker or blows
fuses.
Motor starter failure.
Examine motor starter for burned or
failed components. If damage is
found, replace motor starter. If motor
starter looks okay but is still suspect,
you have two options: have a qualified
electrician test the motor starter for
function, or purchase a new starter
and establish if that was the problem
on change out.
If you have access to a voltmeter, you
can separate a starter failure from a
motor failure by first, verifying
incoming voltage at 220+/-20 and
second, checking the voltage between
starter and motor at 220+/-20.
If incoming voltage is incorrect, you
have a power supply problem.
If voltage between starter and motor is
incorrect, you have a starter problem.
If voltage between starter and motor is
correct, you have a motor problem.
Motor failure.
If electric motor is suspect, you have
two options: Have a qualified
electrician test the motor for function
or remove the motor and take it to a
quality electrical motor repair shop
and have it tested.
Miswiring of the machine.
Double check to confirm all electrical
connections are correct. Refer to
wiring diagram to make any needed
corrections.
Switch failure.
If a start, stop, or table movement
switch is suspect, you have two
options: Have a qualified electrical
test the switch for function, or
purchase a new switch and establish
it that was the problem on change out.
Planer does not come
up to speed.
Low current.
Contact a qualified electrician.
Summary of Contents for IP-2008-HD
Page 28: ...25 25 All measurements are shown below knife Adjustment Dimensions...
Page 42: ...39 39 6 Loosen Nut on motor bracket 7 Remove belt 8 Remove cutterhead pulley...
Page 46: ...43 43...
Page 50: ...47 47 PARTS DIAGRAM...
Page 51: ...48 48...
Page 52: ...49 49...
Page 53: ...50 50...
Page 54: ...51 51...