11
11
•
Improper connection of the equipment-grounding conductor can result in risk of electric
shock. The conductor with insulation having an outer surface that is green with or without
yellow stripes is the equipment-grounding conductor. If repair or replacement of the electric
cord or plug is necessary, do not connect the equipment-grounding conductor to a live
terminal.
•
Check with a qualified electrician or service personnel if the grounding instructions are not
completely understood, or if in doubt as to whether the tool is properly grounded.
•
Repair or replace damaged or worn cord immediately.
Extension Cord Safety
Extension cord should be in good condition and meet the minimum wire gauge requirements listed
below:
LENGTH
AMP RATING
25ft
50ft
100ft
0-6
16
16
16
7-10
16
16
14
11-12
16
16
14
13-16
14
12
12
17-20
12
12
10
21-30
10
10
No
WIRE GAUGE
An undersized cord decreases line voltage, causing loss of power and overheating. All cords
should use a ground wire and plug pin. Replace any damaged cords immediately.
Plug Connection
1. Have an electrician install the correct plug for the application.
2. Once hooked up, turn on the power supply and start the machine.
Summary of Contents for PH-19VS
Page 20: ...18 18 PARTS DIAGRAM Main Frame Assembly ...
Page 21: ...19 19 Back Stop Assembly ...
Page 22: ...20 20 Toggle Assembly ...
Page 23: ...21 21 Release Eccentric Assembly ...
Page 24: ...22 22 Crankshaft Assembly ...
Page 25: ...23 23 Release Pin Assembly ...
Page 26: ...24 24 Guard Assembly ...
Page 27: ...25 25 Single Phase Power System ...
Page 28: ...26 26 Three Phase Power System ...
Page 33: ...31 31 NOTES ...
Page 34: ...32 32 NOTES ...
Page 35: ...33 33 NOTES ...
Page 36: ...34 34 ...