TROUBLESHOOTING
FAULT
PROBABLE CAUSE
REMEDY
Motor does not start
No power.
Blown fuse.
Motor burned out.
Check power supply for 110V,
60hz.
Check and replace fuse.
Replace motor.
Indicator light not lit
Light burned out
Blown fuse.
No power
Replace indicator light.
Check and replace fuse.
Check power supply for 110V,
60hz.
Table fails to turn
Faulty foot switch.
Toggle switch in
STOP
position.
Speed adjustment knob set to
zero.
Motor burned out.
Faulty circuit board
Check and replace foot switch.
Select either
FOR
. or
REV
.
Increase setting to 10 or more
to see movement.
Replace motor.
Replace circuit board.