135
Chapter 5
GENERAL
ROOM HEATER - FAULT FINDING
FAULT -
Heater will not light
Symptoms
Cause
Cure
Spark visible
No gas. Bottle temperature too low
Check bottle and taps. See gas
supply notes.
Regulator malfunction.
See gas supply notes.
Overgassed. Refer to lighting
instructions.
Turn off. Wait 3 mins.
No spark
.
Piezo failure.
Seek service attention.
HT lead shorting to earth or broken.
Check and insulate or repair.
FAULT -
Heater lights
Symptoms
Cause
Cure
Goes out
Knob released too soon or not fully
Refer to lighting instructions.
when knob
depressed.
is released.
Thermocouple or valve failure.
Seek service attention.
Goes out after
Bottle temperature too low.
See gas supply notes.
a time.
Chimney intake or flue partly blocked.
Check and clear.
Goes out
Flue disconnected or damaged.
Turn heater out immediately.
when door
is slammed.
Seek service attention.
FAULT -
Blown Air
Symptoms
Cause
Cure
Not working.
Supply fuse blown.
Replace.
Running slowly.
Hair or dust in fan wheel. Check
Electrically isolate and clear with
balance of blown air system and
brush.
close/open to balance system
Blowing on
one leg of
system only.
12 V systems only:- Supply reversed.
Correct.
Summary of Contents for 2002 Series
Page 1: ...Bailey of Bristol 2002 Series Owners Manual...
Page 2: ......
Page 15: ...9 Chapter 2 CARAVAN TOW VEHICLE MAYBE NO YES EQUAL 85...
Page 52: ...46 Chapter 3 CARAVAN SERVICE SYSTEMS...
Page 57: ...51 Chapter 3 CARAVAN SERVICE SYSTEMS CONTROL PANEL SPB2...
Page 135: ...129 Chapter 5 GENERAL ASSEMBLING THE BUNKS 2 1 5 4 3 6...
Page 146: ...140 Chapter 6 TECHNICAL INFORMATION 230 VOLT 12 VOLT PRIMARY CIRCUIT DIAGRAM RANGER...
Page 147: ...141 Chapter 6 TECHNICAL INFORMATION 230 VOLT 12 VOLT PRIMARY CIRCUIT DIAGRAM SENATOR...
Page 160: ...154 Chapter 6 TECHNICAL INFORMATION NOTES...
Page 161: ...155 Chapter 6 TECHNICAL INFORMATION NOTES...
Page 163: ......
Page 164: ...Bailey of Bristol South Liberty Lane Bristol BS3 2SS England www bailey caravans co uk...