Troubleshooting table
Lockout
Condition
Fault
Remedy
Seattle Control
Panel Prompt
1
No Flame
Detected
Check gas supply making sure there is gas
in the bottle and no blockage in the gas line.
Ensure that if the temperature is below 5°C, only
propane gas is used. Clear lockout as described
on the Seattle control panel.
Space Heater
Ignition Fault
Press Enter To
Clear Lockout
Water Heater
Ignition Fault
Press heater
reset
Button (fig. 2)
to clear lockout
2
Overheat
Check the air ducts and vents are not blocked or
restricted. Whale recommends that you wait at
least 5 to 10 minutes to allow the Space Heater
to cool before clearing lockout as described on
the Seattle control panel.
Space Heater
Overheat Fault
Press Heater
reset
Button (fig. 1) to
clear lockout
Water Heater
Overheat Fault
Press Heater
Reset
Button (fig. 2)
to clear lockout
3
Low/High
Supply
Voltage
Space Heater
Note that if high electric setting is used the
minimum operating voltage is 11.5V, maximum is
15V, when measured at the Space Heater. Check
battery voltage. If between 11.5V and 15V, check
connections between Space Heater and battery.
Check alternator or external battery charging.
Clear lockout as described on the Seattle control
panel.
Space Heater
Voltage Vault
Press Enter to
Clear Lockout
Water Heater
Minimum operating voltage is 10V d.c., maximum
is 15V d.c., when measured at the heater. Check
battery voltage. If between 10V d.c.and 15V d.c.,
check connections between heater and battery.
Check alternator or external battery charging.
Clear lockout as described on the Seattle control
panel.
Water Heater
Voltage Fault
Press Enter to
Cycle Power
90
THE WHALE SP
A
CE AND W
A
TER HEA
TER
Summary of Contents for Approach Advance 615 2017
Page 1: ...OWNER S MANUAL ...
Page 10: ......
Page 25: ......
Page 33: ......
Page 59: ......
Page 134: ......
Page 140: ......
Page 162: ......
Page 176: ...SERVICE MANUAL ...
Page 177: ......
Page 179: ...Motorhome Overview 4 ...
Page 187: ...12 ...
Page 188: ...13 ...