background image

WARNING notices as used in this instruction apply to hazards or unsafe practices that could result in
personal injury or death.

CAUTION notices apply to hazards or unsafe practices that could result in property damage.

NOTES highlight procedures and contain information that assists the operator in understanding the
information contained in this instruction.

WARNING

INSTRUCTION MANUALS

DO NOT INSTALL, MAINTAIN, OR OPERATE THIS EQUIPMENT WITHOUT READING, UNDERSTANDING,
AND FOLLOWING THE PROPER Elsag Bailey INSTRUCTIONS AND MANUALS; OTHERWISE, INJURY OR
DAMAGE MAY RESULT.

RADIO FREQUENCY INTERFERENCE

MOST ELECTRONIC EQUIPMENT IS INFLUENCED BY RADIO FREQUENCY INTERFERENCE (RFI). CAU-
TION SHOULD BE EXERCISED WITH REGARD TO THE USE OF PORTABLE COMMUNICATIONS EQUIP-
MENT IN THE AREA AROUND SUCH EQUIPMENT. PRUDENT PRACTICE DICTATES THAT SIGNS
SHOULD BE POSTED IN THE VICINITY OF THE EQUIPMENT CAUTIONING AGAINST THE USE OF POR-
TABLE COMMUNICATIONS EQUIPMENT.

POSSIBLE PROCESS UPSETS

MAINTENANCE MUST BE PERFORMED ONLY BY QUALIFIED PERSONNEL AND ONLY AFTER SECURING
EQUIPMENT CONTROLLED BY THIS PRODUCT. ADJUSTING OR REMOVING THIS PRODUCT WHILE IT IS
IN THE SYSTEM MAY UPSET THE PROCESS BEING CONTROLLED. SOME PROCESS UPSETS MAY
CAUSE INJURY OR DAMAGE.

AVERTISSEMENT

MANUELS D’OPÉRATION

NE PAS METTRE EN PLACE, RÉPARER OU FAIRE FONCTIONNER L’ÉQUIPEMENT SANS AVOIR LU,
COMPRIS ET SUIVI LES INSTRUCTIONS RÉGLEMENTAIRES DE Elsag Bailey. TOUTE NÉGLIGENCE À
CET ÉGARD POURRAIT ÊTRE UNE CAUSE D’ACCIDENT OU DE DÉFAILLANCE DU MATÉRIEL.

PERTURBATIONS PAR FRÉQUENCE RADIO

LA PLUPART DES ÉQUIPEMENTS ÉLECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR
FRÉQUENCE RADIO. DES PRÉCAUTIONS DEVRONT ÊTRE PRISES LORS DE L’UTILISATION DU MATÉ-
RIEL DE COMMUNICATION PORTATIF. LA PRUDENCE EXIGE QUE LES PRÉCAUTIONS À PRENDRE
DANS CE CAS SOIENT SIGNALÉES AUX ENDROITS VOULUS DANS VOTRE USINE.

PERTURBATIONS DU PROCÉDÉ

L’ENTRETIEN DOIT ÊTRE ASSURÉ PAR UNE PERSONNE QUALIFIÉE EN CONSIDÉRANT L’ASPECT
SÉCURITAIRE DES ÉQUIPEMENTS CONTRÔLÉS PAR CE PRODUIT. L’AJUSTEMENT ET/OU L’EXTRAC-
TION DE CE PRODUIT PEUT OCCASIONNER DES À-COUPS AU PROCÉDÉ CONTRÔLE LORSQU’IL EST
INSÉRÉ DANS UNE SYSTÈME ACTIF. CES À-COUPS PEUVENT ÉGALEMENT OCCASIONNER DES
BLESSURES OU DES DOMMAGES MATÉREILS.

NOTICE

The information contained in this document is subject to change without notice.

Elsag Bailey, its affiliates, employees, and agents, and the authors and contributors to this publication specif-
ically disclaim all liabilities and warranties, express and implied (including warranties of merchantability and
fitness for a particular purpose), for the accuracy, currency, completeness, and/or reliability of the information
contained herein and/or for the fitness for any particular use and/or for the performance of any material and/
or equipment selected in whole or part with the user of/or in reliance upon information contained herein.
Selection of materials and/or equipment is at the sole risk of the user of this publication.

This document contains proprietary information of Elsag Bailey, Elsag Bailey Process Automation, and
is issued in strict confidence. Its use, or reproduction for use, for the reverse engineering, development
or manufacture of hardware or software described herein is prohibited. No part of this document may be
photocopied or reproduced without the prior written consent of Elsag Bailey.

Summary of Contents for Infi 90 NIAC03

Page 1: ...Process Control and Automation Solutions from Elsag Bailey Group E96 425 Analog Input Calibration Module NIAC03...

Page 2: ...UIPEMENTS LECTRONIQUES SONT SENSIBLES AUX PERTURBATIONS PAR FR QUENCE RADIO DES PR CAUTIONS DEVRONT TRE PRISES LORS DE L UTILISATION DU MAT RIEL DE COMMUNICATION PORTATIF LA PRUDENCE EXIGE QUE LES PR...

Page 3: ...nputs for the IMASM03 Analog Slave Module This manual explains how to install and use the NIAC03 mod ule on the INFI 90 Strategic Process Management System It has sections that describe the setup and...

Page 4: ...gh 1 5 Original 2 1 through 2 5 Original 3 1 Original 4 1 Original 5 1 Original A 1 Original Index 1 Original NOTE On an updated page the changed text or table is indicated by a vertical bar in the ou...

Page 5: ...slot Failure to do so could result in damage to the module p 2 4 4 1 AVERTISSEMENTS D ORDRE G N RAL Environnement de l quipement Ne pas soumettre les composants une atmosph re corrosive lors du transp...

Page 6: ...ATION 2 2 Jumper Settings 2 2 Cable Installation 2 2 Module Installation 2 5 SECTION 3 MAINTENANCE 3 1 INTRODUCTION 3 1 MAINTENANCE SCHEDULE 3 1 SECTION 4 REPAIR REPLACEMENT PROCEDURES 4 1 INTRODUCTIO...

Page 7: ...of Tables 1 1 Reference Documents 1 4 1 2 Glossary of Terms and Abbreviations 1 4 1 3 Nomenclature 1 4 1 4 Specifications 1 5 2 1 NIAC03 Module Cable Applications 2 3 3 1 Maintenance Schedule 3 1 A 1...

Page 8: ...module into operation only after reading and understanding this instruction MODULE DESCRIPTION The NIAC03 module is a single printed circuit board that uses one slot in a NTMU01 or NTMU02 Termination...

Page 9: ...input calibration for the 100 ohm RTD inputs on the IMASM03 module Individual channel precision calibration resistors Jumpers select correct resistance for zero or span calibra tion for each channel...

Page 10: ...epair parts training docu mentation etc available from Bailey Controls Company Appendix A Provides a quick reference of dipswitch settings for the IMASM03 Analog Slave Module HOW TO USE THIS MANUAL Re...

Page 11: ...level operations as directed by a master mod ule TMU Termination mounting unit A card cage that provides housing for INFI 90 Network 90 termination mod ules Network 90 is a registered trademark of Els...

Page 12: ...58 F 5 to 90 5 up to 55 C 131 F noncondensing 5 to 40 5 up to 70 C 158 F noncondensing Atmospheric Pressure Air Quality Sea level to 3 km 1 86 mi Noncorrosive Cooling Requirements No cooling is necess...

Page 13: ...d static safe practices when working with modules 1 Use Static Shielding Bag Keep the modules in static shielding bag until you are ready to install them in the system Save the bag for future use 2 Gr...

Page 14: ...input Each jumper selects zero or span for its respective input The IMAMM03 master module issues the calibration commands to the IMASM03 slave module being calibrated To calibrate the zero place the...

Page 15: ...NIAC03 Module Jumper Locations Figure 2 2 Cable Connections for the NIAC03 Module JUMPERS NIAC03 P1 1 29 T00618A CH1 SPAN ZERO CH7 SPAN ZERO CH6 SPAN ZERO CH5 SPAN ZERO CH4 SPAN ZERO CH3 SPAN ZERO CH2...

Page 16: ...he TMU backplane slot assigned to the NIAC03 module The cable should latch securely in place Card edge connector P1 of the NIAC03 mod ule connects to this end of the cable 5 Replace or add the cable r...

Page 17: ...one slot To install 1 Verify slot assignment of the NIAC03 module 2 Align the NIAC03 module with the guide rails in the TMU card rack and insert the module The NIAC03 module is ready for operation if...

Page 18: ...maintenance schedule MAINTENANCE SCHEDULE Execute the tasks in Table 3 1 at the specified intervals Table 3 1 Maintenance Schedule Task Interval Clean and tighten all power and grounding connections...

Page 19: ...er 2 Slide the calibration module out of the cabinet 3 Slide the new calibration module into the same slot as the module that was removed 4 Verify that cabling to the calibration module is correct 5 F...

Page 20: ...er and quantity 2 Model and serial numbers if applicable 3 Bailey instruction manual number page number and refer ence figure that identifies the part Order parts without commercial descriptions from...

Page 21: ...g the NIAC03 module Figure A 1 shows the IMASM03 module address select switch SW1 Table A 1 lists the binary addresses for setting SW1 Refer to the IMAMM03 instruction for more detailed informa tion t...

Page 22: ...ser 1 1 M Maintenance schedule 3 1 Module description 1 1 N NIAC03 Cable Applications 2 4 Cable Connections 2 3 Jumper Locations 2 3 Nomenclature 1 4 O Overview 1 1 R Reference documents 1 3 Replaceme...

Page 23: ...8756 ASIA PACIFIC 152 Beach Road Gateway East 20 04 Singapore 189721 Telephone 65 391 0800 Telefax 65 292 9011 EUROPE AFRICA MIDDLE EAST Via Puccini 2 16154 Genoa Italy Telephone 39 10 6582 943 Telefa...

Reviews: