TROUBLESHOOTING
56
OWNER’S MANUAL |
TROUBLESHOOTING
1 800 463.2187
From 8 a.m. to 8 p.m. Monday to Thursday (EST) . From 8 a.m. to 5 p.m. on Friday (EST)
Printed in Canada. Copyright © May 2017 BainUltra Inc. All rights reserved. 45220001
Some products, specifications, and services mentioned in this manual are described in pending patent applications or are protected by patents.
TROUBLESHOOTING
SITUATION
SOLUTIONS
Air jets seem cool.
LED does not work.
Temperature of air injected into bath is directly proportional
to the speed of the turbine. The higher the speed, the
warmer the air is. A simple way to check if your air-heater or
heaters are working properly is to turn on the system at the
highest speed (if your control offers a range of intensities)
with no water in the bath (there is absolutely no risk to the
system). After 3 to 5 minutes, the heated backrest or
backrests should be warm to the touch and jets should also
seem warm when you bring your hands close to them.
• Check the turbine air intake. It should not be too cold nor
too warm. Ideally, the temperature should be between
72°F (20°C) and 86°F (30°C).
• Check that distance between turbine and bath is not too
great. If possible, insulate air line along its entire length.
See turbine installation section of this manual.
An LED has a 100 000-hour lifecycle.
• Verify wiring and connections.
IMPORTANT: THESE INSTRUCTIONS ONLY APPLY IF
THE LED CAN BE ACCESSED FROM BATH
EXTERIOR.
• Upon verification, if LED still does not work, disconnect
and replace the LED by doing the following:
- Remove the LED module by pulling on the white part of
the plug. If the module is difficult to remove, use a pair of
vice-grips.
- Detach the wire from the bath.
- Unplug the wire from the chromatherapy control module.
- Plug the wire into the chromatherapy control module.
- Plug the LED module back into its socket.
NOTE: IT IS NOT NECESSARY TO REATTACH THE WIRE