HYDRO-QUIP PORTABLE SPA EQUIPMENT
IF YOU APPLY POWER TO SYSTEM AND DO NOTHING ELSE:
1. The primary filter cycle will occur in 24 hours and run for 120 min.
This will repeat every 24 hours.
2. The spa will heat up to and maintain 100º F.
(The freeze protection mode is available if required.)
TO SET OR CHANGE THE FILTER CYCLE START TIMES:
Refer to
PROGRAMMING FILTER CYCLES
in operating manual.
IF THE FILTER CYCLES ARE NOT RUNNING AT THE BEST TIMES FOR YOUR
SLEEPING SCHEDULE, YOU MUST PROGRAM THE SYSTEM AT A PARTICULAR
TIME OF DAY TO ADJUST THE INTERNAL SYSTEM TIME PATTERN.
Desired Filter Cycles Programming Time Filtering Time
1 Cycle per 24 Hour Period 8:00 PM 8:00 PM
2 Cycles per 24 Hour Period 8:00 PM 8:00 PM & 8:00 AM
3 Cycles per 24 hour Period 2:00 PM 10:00 PM, 6:00 AM
& 2:00 PM
Note: The easiest way to change the internal system time pattern is to simply TURN
OFF ALL POWER to the spa for (10) ten seconds and then promptly start your
programming procedure.
QUICK PROGRAMMING NOTES
11
SPORTUB 1057-58 WIRING DIAGRAM
All Universal systems leave configured 120-Volt input power.
240-Volt electrical service required:
Line 1, Line 2, and Ground. 8AWG. Minimum
L1
GR L2
N
IMPORTANT:
Always refer to the
product data label (located on
top of Control Box) for specific
electrical information
Summary of Contents for sportub series