50
2) Charging Coil
First connect the + ve meter lead to Violet cable and
- ve meter lead to Black (earth). The resistance value
should be as tabulated below.:
Range
Connection
Reading
Meter +ve
Meter -ve
x10ohms Violet Black 245 to 295ohms
3) Pulser Coil
First connect the + ve meter lead to Grey cable and - ve
meter lead to Black (earth). The resistance value should
be as tabulated below.:
Range
Connection
Reading
Meter +ve
Meter -ve
x10 ohms
Grey Black
108 to 132ohms
4) Battery Charging Coil
First connect the + ve meter lead to Orange cable and -
ve meter lead to Blue/Red. The resistance value should
be as tabulated below.:
Range
Connection
Reading
Meter +ve
Meter -ve
x10ohms Yellow Yellow/Red 0.65 to 0.95 ohms
5) Insulation Check (ForLighting,Horn,Battery
Charging coils & Charging coils)
: To check
whether coil is body short
Note : Disconnect wire connected to earth for lighting &
charging coil before conducting insulation check.
Range
Connection
Reading
Meter +ve
Meter -ve
x1 K
Core
Either one >200 K
ohms
ohms
(Remove varnish
of terminal
from core to have
proper contact
F) DC VOLTAGE REGULATOR
DC Voltage Measurement :
l
Cve lead of meter to +ve terminal of Battery
and - ve terminal of meter to - ve terminal of Battery.
l
Ensure that all lights are off.
l
Start the Engine, set it at 3500 RPM .
l
Measure the Battery terminal voltage.
LOAD
METER
READING AT 4500 RPM
OFF
DC 25 V
14.7 ±1V
Note : Use fully charged Battery ( specific gravity of
electrolyte = 1.24)
G) BATTERY CHARGING SYSTEM
l
Ensure that battery is fully charged.
l
Set meter range at 20 A DC
l
Remove fuse & connect meter +ve lead to other
terminal of fuse i.e. Red / White wire coming from
DC Regulator and meter - ve lead to Red wire coming
from bve terminal.
l
All DC load viz. Brake lights and Side indicator bulbs
are to be switched OFF.
l
Start the Engine. Set the Engine RPM at 3500 RPM.
l
Measure Battery charging current. It should be 1.0 to
3.0 amps i.e. current must flow into the Battery.
Range
Connection
Reading
Meter +ve
Meter -ve
20A DC
Red/White
Red
1.0 to 3.0A
l
Stop the Engine. Disconnect the meter and reconnect
the fuse.
l
As a further check, set meter range at 25 V DC.
l
Cve lead of meter to +ve terminals of Battery
and - ve terminal of meter to - ve terminal of Battery.
l
Ensure that all lights are off.
l
Start the Engine.
l
As the RPM of engine increases, voltage will also
increase. Measure the Battery terminal voltage at
3500 RPM.
Range
Connection
Reading
Meter +ve
Meter -ve
25V DC
Bve
Bve
14.7±1 V
Note : Use fully charged Battery ( specific gravity of
electrolyte = 1.24)
H) TURN SIGNAL RELAY
Remove the flasher unit which is to be checked and
connect it to another vehicle whose flasher unit and side
indicators are working properly. Check that the terminals
are connected correctly. Start the vehicle and put ON the
indicator switch and see if the flasher unit functions or not.
If flasher unit works properly then there may be some
problem with the switch or regulator or with the wiring of
the vehicle whose flasher unit is being checked.
Also check flash rate (No.of flashes/min). If flash rate is
not within the specified limit i.e.90 ±30 flashes / min,
replace it as it is faulty.
If right or left signal gets ON, check that the blinker bulbs
are Ok.
I) FUEL LEVEL GAUGE (TANK UNIT)
For knowing the quantity of fuel inside the fuel tank at a
glance, fuel gauge is provided on an instrument panel. The
fuel gauge works on the principle of 'variable resistance'.